Operating Instructions
Table Of Contents
- 1. Introduction
- 2. Technical customer support
- 3. Functional description
- 4. Unpacking, transporting, storing
- 5. Technical data – Device
- 6. Technical data – Radio modules (all optional)
- 7. Operation
- 8. General device configuration
- 9. Wi-Fi configuration
- 10. WWAN configuration
- 11. Mechanical installation
- 12. Electrical installation, cable connection, cable cover
- 13. Connectors
- 14. Integrated power supply, power supply cable
- 15. Optional equipment
- 16. Maintenance
- 17. Malfunctions and troubleshooting
- 18. Reasonably foreseeable misuse
- 19. Guidelines and certificates
- 20. End-of-life device disposal
- 21. List of figures
Optional equipment
DLT-V72 Operating Instructions V2.50 Preliminary 119 / 140
15.1.1. Battery pack specifications
Two battery pack types are available:
Lithium-ion battery pack I
Bridging time The integrated UPS can bridge an interruption of the main
supply for typically 20 minutes. Requirement: The battery pack
is fully charged.
Operating temperature -20 to +40 °C
Charging time 4 h (fully recharge a completely discharged battery pack)
Charging temperature -10 to +30 °C (ambient temperature)
Storage temperature -20 to +60 °C
Maximum output power 40 W
Battery voltage 7,2 V
Battery capacity 2500 mAh
Lithium-ion battery pack II
Bridging time The integrated UPS can bridge an interruption of the main
supply for typically 20 minutes. Requirement: The battery pack
is fully charged.
Operating temperature -30 to +50 °C
Charging time 4 h (fully recharge a completely discharged battery pack).
Charging temperature -10 to +50 °C (ambient temperature)
Storage temperature -30 to +60 °C
Maximum output power 40 W
Battery voltage 7,2 V
Battery capacity 2000 mAh