15.1.1. Battery pack specifications
Two battery pack types are available:
Lithium-ion battery pack I
Bridging time The integrated UPS can bridge an interruption of the main
supply for typically 20 minutes. Requirement: The battery pack
is fully charged.
Operating temperature -20 to +40 °C
Charging time 4 h (fully recharge a completely discharged battery pack)
Charging temperature -10 to +30 °C (ambient temperature)
Storage temperature -20 to +60 °C
Maximum output power 40 W
Battery voltage 7,2 V
Battery capacity 2500 mAh
Lithium-ion battery pack II
Bridging time The integrated UPS can bridge an interruption of the main
supply for typically 20 minutes. Requirement: The battery pack
is fully charged.
Operating temperature -30 to +50 °C
Charging time 4 h (fully recharge a completely discharged battery pack).
Charging temperature -10 to +50 °C (ambient temperature)
Storage temperature -30 to +60 °C
Maximum output power 40 W
Battery voltage 7,2 V
Battery capacity 2000 mAh