User's Manual

Mechanical Installation
142 / 189
12.2.1. Mounting the DLT-V72 at the deployment location
WARNING
Risk of injury and damage due to improper deployment
location.
1. Observe the intended use of the DLT-V72, e.g. not in potentially
explosive areas, not in life-supporting facilities.
2. Ensure that the deployment location of the DLT-V72 complies
with the permissible environmental conditions.
3. The installation height of the device shall not exceed 2 m.
4. When installing the DLT-V72, make sure that if the bracket
breaks (e.g. because of a stress fracture) no one will be injured.
5. Alternatively please put appropriate safety measures in place
(e.g. install a security cable in addition to the mounting bracket).
6. To ensure that the limits set for exposure to radio waves are not
exceeded: Install the DLT-V72 so that persons maintain a
minimum distance of 20 to 50 cm to the antenna.
Never install the system in a closed environment without cooling air!
NOTICE
Prevent system malfunction and property damage
Installation environment without cooling air can overheat / damage the
DLT-V72.
The DLT-V72 employs a passive cooling concept whereby the waste
heat generated inside the device is emitted from the surface of the
housing. For this system to function properly, sufficient fresh air
circulation is required. If there is no access to fresh cooling air, it may
result in overheating and severe damage to the device.
Never install the system in a closed environment where the cooling air
is unable to dissipate accumulated heat to the outside.
The maximum permissible ambient temperature for the entire system
needs to be taken into account for the specific application area.