EKI-4524RI 24-port 10/100TX + 2-port 100 Mini-GBIC Ethernet Switch with AC/DC Power Input and Wide Operating Temperature EKI-4524ARI 24-port 10/100TX + 2-port 100 Mini-GBIC Ethernet Switch with Wide Operating Temperature User Manual
Copyright The documentation and the software included with this product are copyrighted 2011 by Advantech Co., Ltd. All rights are reserved. Advantech Co., Ltd. reserves the right to make improvements in the products described in this manual at any time without notice. No part of this manual may be reproduced, copied, translated or transmitted in any form or by any means without the prior written permission of Advantech Co., Ltd. Information provided in this manual is intended to be accurate and reliable.
Product Warranty (2 years) Advantech warrants to you, the original purchaser, that each of its products will be free from defects in materials and workmanship for two years from the date of purchase. This warranty does not apply to any products which have been repaired or altered by persons other than repair personnel authorized by Advantech, or which have been subject to misuse, abuse, accident or improper installation.
Declaration of Conformity CE This product has passed the CE test for environmental specifications. Test conditions for passing included the equipment being operated within an industrial enclosure. In order to protect the product from being damaged by ESD (Electrostatic Discharge) and EMI leakage, we strongly recommend the use of CE-compliant industrial enclosure products.
Safety Instructions 1. Read these safety instructions carefully. 2. Keep this User's Manual for later reference. 3. Disconnect this equipment from any AC outlet before cleaning. Use a damp cloth. Do not use liquid or spray detergents for cleaning. 4. For plug-in equipment, the power outlet socket must be located near the equipment and must be easily accessible. 5. Keep this equipment away from humidity. 6. Put this equipment on a reliable surface during installation.
Safety Precaution - Static Electricity Follow these simple precautions to protect yourself from harm and the products from damage. 1. To avoid electrical shock, always disconnect the power from your equipment chassis before you work on it. 2. Disconnect power before making any configuration changes.
Contents Overview........................................... 2 Chapter 1 1.1 Introduction ........................................................... 2 1.1.1 The SFP Advantage....................................... 2 1.1.2 High-Speed Transmissions ............................ 2 1.1.3 19” Rack Mounting ......................................... 2 1.1.4 Advanced Protection ...................................... 2 1.1.5 Easy Troubleshooting .................................... 2 1.2 Features .................
EKI-4524RI & ARI_User Manual viii
CHAPTER Overview Sections include: z Introduction z Features z Specifications z Packing List z Safety Precaution 1 Chapter1
Chapter 1 Overview 1.1 Introduction The EKI-4524RI/4524ARI is a cost-effective solution, which meets the high reliability requirements demanded by industrial applications. The equipment is able to operate in wide temperature environments and supports variants of power input. Besides, the EKI-4524RI/4524ARI is designed for the applications supposed to have certain electric interference. Equipped with isolated power and isolated communication ports, the device has high resistance toward electrical noise.
1.2 Features • System Interface/Performance ¾ RJ-45 ports support Auto MDI/MDI-X Function ¾ 2 x 100Mbps SFP (mini-GBIC) ports supported for long distance up-linking ¾ Store-and-Forward Switching Architecture ¾ Back-plane (Switching Fabric): 5.
1.3 Specifications Communications IEEE Standard LAN Transmission Distance Transmission Speed IEEE 802.3, 802.3u, 802.
Environment Operating Temperature Operating Humidity Storage Temperature Storage Humidity -40 ~ 75oC (-40 ~ 167oF) 5 ~ 95% (non-condensing) -40 ~ 85oC (-40 ~ 185oF) 5 ~ 95% (non-condensing) Certifications Standard EMC Freefall Shock Vibration Meets IEC 61850-3 & IEEE 1613 FCC Class A CE EN61000-6-4 CE EN61000-6-2 CE EN61000-4-2 (ESD) CE EN61000-4-3 (RS) CE EN61000-4-4 (EFT) CE EN61000-4-5 (Surge) CE EN61000-4-6 (CS) CE EN61000-4-8 (Magnetic Field) IEC60068-2-32 IEC60068-2-27 IEC60068-2-6 5 Chapter1
1.4 Packing List • • • • 1 x EKI-4524RI/4524ARI Series Industrial Unmanaged Fast Ethernet Switch 1 x eAutomation Industrial Communication CD-ROM and User manual 2 x Rackl Mounting Bracket and Screws 1 x EKI-4524RI/4524ARI Startup Manual 1.5 Safety Precaution Attention IF DC voltage is supplied by an external circuit, please use a protection device on the power supply input.
CHAPTER Installation Sections include: z LED Indicators z Dimensions z Mounting z Network Connection z Connection to a Fiber Optic Network z Power Connection 7 Chapter2
Chapter 2 Installation In this chapter, you will be given an overview of the EKI-4524RI/4524ARI hardware installation procedures. 2.1 LED Indicators The LED indicators located on the panel display the power status and network status of EKI4524RI/4524ARI; each has its own specific meaning as the table shown below. Table 2.
2.2 Dimensions (units: mm) Figure 2.1: EKI-4524RI Mechanical Dimensions Figure 2.
2.3 Mounting 2.3.1 Rack mounting EKI-4524RI/4524ARI comes with a rack-mounted kit and can be mounted in an EIA standard size, 19inch rack. The Switch can be placed in a wiring closet with other equipment. Perform the following steps to rack-mount the switch: 1. Position one bracket to align with the holes on one side of the switch and secure it with the smaller bracket screws. Then attach the remaining bracket to the other side of the Switch. Figure 2.3: Attach mounting brackets with screws 2.
2.4 Network Connection The EKI-4524RI/4524ARI has 24 x RJ-45 ports that support connection to 10 Mbps Ethernet, or 100 Mbps Fast Ethernet, and half or full duplex operation. EKI-4524RI/4524ARI can be connected to other hubs or switches via a twisted-pair straight-through or crossover cable up to 100m long. The connection can be made from any TX port of the EKI-4524RI/4524ARI (MDI-X) to another hub or switch either MDI-X or uplink MDI port.
Figure 2.6: Transceiver Inserted Second, insert the fiber cable of LC connector into the transceiver. Figure 2.
To remove the LC connector from the transceiver, please follow the steps shown below: First, press the latches of the LC connector and pull it out from the transceiver. Figure 2.8: Removing the LC Connector Second, push down the transceiver handle and pull it out by the plastic handle. Figure 2.
2.6 Wiring the Power Input EKI-4524RI Power Input Wiring EKI-4524RI comes equipped with a 10-position cross screw terminal block on where power input and failsafe relay are located. Please follow the steps below to wire the power connection. Table 2.2: Terminal Block Pinouts Pin Number 1. 2. 3. 4. Description Definition 1 N Neutral pin is wired to the Neutral point of the AC power system, or to the negative (-) point of the DC power source.
EKI-4524ARI Power Input Wiring 1. Insert DC power wires into the contacts. Pin 5: Negative Pin 6: Positive Pin 3 & 4: P-Fail Contacts Pin 1 & 2: NC Figure 2.11: Power Contacts of the Terminal Block 2. Tighten the wire-clamp screws to prevent the wires from loosing. Note • • Use Copper Conductors Only, 60/75°C, tightening to 5 lb-in. The wire gauge for the terminal block should be in the range between 12~ 24 AWG.
2.7 Wiring the Fail-Safe Alarm Contacts With a Normally Close circuit formed by wiring with an external power and an alarm device (a buzzer or a flashing LED), system will detect the power failure event. If a failure event occurs, the relay inside the equipment will act as an open switch, and therefore break the external circuit. The fail-safe design is intended for triggering the connected alarm device for warning purposes.
CHAPTER Troubleshooting 17
Chapter 3 Troubleshooting Verify that you are using the right power cord/adapter. Please don’t use a power adapter with DC outputs higher than the power rating of this equipment, or it will be damaged. Select the proper UTP cable to construct the user network.
APPENDIX Pin Assignment & Wiring 19
Appendix A Pin Assignments & Wiring It is suggested to adopt ELA/TIA as the wiring of the RJ-45. Figure A.1: RJ-45 Pin Assignment Figure A.2: EIA/TIA-568B Figure A.
APPENDIX Compatible SFP Transceivers 21
Appendix B Compatible SFP Transceivers The table below shows compatible SFP transceivers for EKI-4524RI/4524ARI.