FPM-5151G Series 15" XGA Industrial Monitor with Resistive Touchscreen, Direct-VGA, DVI Ports and DC10-30V Inputs User Manual
Copyright Notice This document is copyrighted by Advantech Co., Ltd. All rights are reserved. Advantech Co., Ltd. reserves the right to make improvements to the products described in this manual at any time. Specifications are thus subject to change without notice. No part of this manual may be reproduced, copied, translated, or transmitted in any form or by any means without the prior written permission of Advantech Co., Ltd. Information provided in this manual is intended to be accurate and reliable.
Product Warranty (2 years) Advantech warrants to you, the original purchaser, that each of its products will be free from defects in materials and workmanship for two years from the date of purchase. This warranty does not apply to any products which have been repaired or altered by persons other than repair personnel authorized by Advantech, or which have been subject to misuse, abuse, accident or improper installation.
FCC Class B This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a residential environment. This equipment generates, uses and can radiate radio frequency energy. If not installed and used in accordance with this user's manual, it may cause harmful interference to radio communications.
Additional Information and Assistance 1. Visit the Advantech web site at www.advantech.com where you can find the latest information about the product. 2. Contact your distributor, sales representative, or Advantech's customer service center for technical support if you need additional assistance.
12. Never pour any liquid into an opening. This may cause fire or electrical shock. 13. Never open the equipment. For safety reasons, the equipment should be opened only by qualified service personnel. 14. If one of the following situations arises, get the equipment checked by service personnel: a. The power cord or plug is damaged. b. Liquid has penetrated into the equipment. c. The equipment has been exposed to moisture. d.
Contents Chapter 1 Introduction ..................................................... 2 1.1 1.2 1.3 1.4 1.5 1.6 Chapter Introduction ....................................................................... 2 Specifications .................................................................... 2 LCD Specification............................................................. 3 Power Consumption .......................................................... 3 Connectors..............................................
C.2.10 C.2.11 C.2.12 C.2.13 FPM-5151G User Manual Mode Information Menu .............................................. 31 Memory Recall Menu .................................................. 32 Exit Menu .................................................................... 33 Hot Keys ......................................................................
CHAPTER 1 2 Introduction This chapter includes: • Introduction • Specifications • LCD Specification • Power Consumption • Connectors • Dimensions
Chapter 1 Introduction 1.1 Introduction Advantech's FPM-5151G is a 15" color TFT LCD flat panel monitor built specifically for industrial applications. With the optional touchscreen, FPM-5151G is an excellent and user-friendly system control interface. In addition to its usual application as an LCD panel monitor, FPM-5151G comes standard with direct VGA and DVI control signal inputs, making it compatible with Industrial PCs and Workstations.
Touchscreen (Optional) • Type: 8 wire, analog resistive • Resolution: 1024 x 1024 • Light Transmission: >80% (Gouge Hardness is greater tahn 4H per ASTM D3363-92 for HCC01, HCG10 and HCG12 • Operating Pressure: 30 ~ 45 gram for stylus pen contact bounce < 10 ms • Controller: USB & RS-232 interface • Power Consumption: +5 V @ 200 mA • OS Support: Win 95/98/ME/2000/XP/CE/NT/Vista, Linux, MS-DOS • Life Span: 100 million activation (typical) at a single point with a 5/8" diameter silicone finger with a 350 g lo
1.5 Connectors The following connectors are situated on the left hand side of the FPM-5151G Series: VGA Port (DB-15) This DB-15 connector can be connected to the system via the external 15-pin DB-15 connector locatd on the left side of the system unit. DVI Port (DVI-D) Connected with a standard DVI connector thru I/O port of this unit. Only supports digital signals Touchscreen Connector (DB-9) (optional) This connector will be present only if a touchscreen is installed.
1.6 Dimensions Figure 1.
FPM-5151G User Manual 6
CHAPTER 2 Mounting • Wallmounting • Panel Mounting • Rack Mounting • Desktop Mounting • Swing Arm Mounting 2
Chapter 2 Mounting 2.1 Mounting the Monitor The FPM-5151G Series can be mounted in many different ways. The versatility of the FPM-5151G mounts enable it to be mounted on your desk or anywhere else. 2.1.1 Wallmounting FPM-5151G can be mounted directly on a wall with panel mounting brackets. Please refer to figure 2-1 and follow the following steps to mount FPM-5151G on a wall: 1. Screw the hook and desk-stand brackets on the wall. 2. Attach 4 screws around the bracket 3.
2.1.2 Panel Mounting FPM-5151G can be mounted directly on a panel with additional mounting brackets. Please refer to figure 2-2 and follow the following steps: 1. Fix 10pcs panel bracket around the industrial monitor 2. Fix into the panel by screw the bracket Figure 2.
2.1.3 Rack Mounting (Optional) If you need to install the FPM-5151G on a rack, you must order the rack mount kit for FPM-5151G (Part Number is FPM-5151G-RMKE). Attach the rack mounting brackets on FPM-5151G with the screws, then affix the monitor in the rack. Figure 2.
2.2 Desktop, Swing-ARM for FPM-5151G The FPM-5151G Series can be mounted in other ways, such as desktop and swing-arm. 2.2.1 Desktop Stand FPM-5151G can be mounted as stand in the desk directly by a additional mounting brackets. Please refer to figure 2-4 and follow these steps: Figure 2.
2.2.2 Swing-ARM (VESA Compliant) FPM-5151G has been designed with support for the VESA Arm standard. Refer to figure 2.5. Supports both 75mm and 100mm VESA dimension. Figure 2.
APPENDIX A 2 Touchscreen
Appendix A Touchscreen A.1 Introduction The FPM-5151G Series optional touchscreen uses advanced 8-wire resistive technology. It provides more accurate sensing capacity than other technologies. The touchscreen is specially designed for tough industrial environments, and has been approved to FCC Class B standards. Note: RS-232 & USB touchscreen interface does not allow connection to the system at the same time. It can be changed by switch. A.2 Touchscreen Specifications 1.
4. Linearity 4.1 Linear Test Specifications Direction X: <1.5 % Direction Y: <1.5 % 4.2 Linearity Test Apply voltage (DC5V) to upper (or lower ) electrodes, output voltage Vx or Vy on the other electrodes is measured at every regular intervals. Linearity is the value of max. error voltage 5. Environment Specifications 5.1 Operating Temperature: -10 ~ + 60° C 5.2 Storage Temperature: -40 ~ +80° C 5.3 Humidity: if 40° C, humidity <80% RH if 40° C, humidity < 90% RH No dew condensation A.
FPM-5151G User Manual 16
B APPENDIX 2 Setting Serial Data for Expansion
Appendix B Setting Serial Data for Expansion B.1 Setting Serial Data for Expansion The twelve kinds of timings below are already programmed in this module. The input synchronous signals are automatically recognized.
C APPENDIX 2 OSD Operation Keypad
Appendix C OSD Operation Keypad C.1 OSD Board Overview The OSD keypad, including six keys and a two color indicator, is designed as the OSD operation interface. Note: This sheet is only for reference, different models will has different styles, but the functionality is the same. C.1.1 OSD Button Description Buttons Descriptions Power Auto/Exit Turn the monitor power ON or OFF. Automatically adjust the clock, phase, H-position and V-position. Exit menu. Activate the volume control.
C.2 OSD Key Functions Each selected value is stored into LCD memory after SEL signal input or time out. The stored values are not affected if the power is turned off. But the selected value is not available in case a selected mode is changed before time out or power is turned off before time out. TIME OUT Æ 5-6 seconds ( Can be set in OSD Manager) The default definition of input keys is shown as following: C.2.
C.2.2 Input Source Select • Generate Main Menu Select by Left and Right Button, press Menu Button for selection confirmation • Main Menu -- DISPLAY IN SCREEN • Sub-Menu – DISPLAY IN SCREEN • Available Key Functions Power Off the LCD Monitor Increase the gauge value of the selected option. Return to last menu Selected to confirm Decrease the gauge value of the selected option.
4. Auto Select Input • ON Æ start from default setting and scan the inputs by following sequence from ANALOG INPUT, DIGITAL INPUT, S-VIDEO INPUT, and CVBS INPUT. • OFF Æ start from default setting C.2.
• Available Key Functions Power Off the LCD Monitor Increase the gauge value of the selected option. Return to last menu Selected to confirm Decrease the gauge value of the selected option. N/A RECALL VALUE – User Define • Rec1 Æ Pressed to record 1st setting as recall value followed by current screen setting • Rec2 Æ Pressed to record 2nd setting as recall value followed by current screen setting • Recall Æ Switch the setting change by Rec1 and Rec2 while pressed C.2.
• Available Key Functions Power Off the LCD Monitor Increase the gauge value of the selected option. Return to last menu Selected to confirm Decrease the gauge value of the selected option.
C.2.5 Color Temperature Menu • Generate Main Menu Select by Left and Right Button, press Menu Button for selection confirmation • Main Menu -- DISPLAY IN SCREEN • Sub-Menu – DISPLAY IN SCREEN • Available Key Functions Power Off the LCD Monitor Increase the gauge value of the selected option. Return to last menu Selected to confirm Decrease the gauge value of the selected option.
C.2.
• Available Key Functions Power Off the LCD Monitor Increase the gauge value of the selected option. Return to last menu Selected to confirm Decrease the gauge value of the selected option. N/A Customization setting for RGB colors C.2.
• Available Key Functions Power Off the LCD Monitor Increase the gauge value of the selected option. Return to last menu Selected to confirm Decrease the gauge value of the selected option. N/A C.2.
• Available Key Functions Power Off the LCD Monitor Increase the gauge value of the selected option. Return to last menu Selected to confirm Decrease the gauge value of the selected option. N/A C.2.
• Available Key Functions Power Off the LCD Monitor Increase the gauge value of the selected option. Return to last menu Selected to confirm Decrease the gauge value of the selected option. N/A Auto configuration can be set in menu and also can press the without any menu indication. C.2.
• Available Key Functions Power Off the LCD Monitor Increase the gauge value of the selected option. Return to last menu Selected to confirm Decrease the gauge value of the selected option. N/A C.2.
• Available Key Functions Power Off the LCD Monitor Increase the gauge value of the selected option. Return to last menu Selected to confirm Decrease the gauge value of the selected option. N/A C.2.
• Available Key Functions Power Off the LCD Monitor Increase the gauge value of the selected option. Return to last menu Selected to confirm Decrease the gauge value of the selected option. N/A C.2.
• Entry OSD UNLOCK MODE • Press HOT KEY, the screen will show this action first • Don’t remove the HOT KEY until the screen indicated this task is finished.
FPM-5151G User Manual 36