Unit installation
INTRAC-305  INSTALLATION 
© 2011 Advantech Wireless  INTRAC-305 MANUAL - Issue 3.2  Page 75 
6 
    Finally adjust R55 to read +20dB when the maximum clear 
sky tracking signal is being received. 
  Note  It may be necessary to adjust the links J31 depending on the 
polarity of the tracking signal. The link options are both links 
should be either vertical or horizontal. 
OPERATIONAL CHECKS     
Manual Operation    This test checks the operation of the motor drives and limit 
switches. 
    Ensure that all limit and interlock switches are in the normal 
operating condition. 
    Switch on the INTRAC. If the System Alarm indicator 
illuminates press the Standby key. If it remains illuminated 
view the Show Alarms display to what is causing the alarm. 
Take the necessary action to clear the cause(s) of the alarm. 
    Select Manual (P) Mode from the New Mode menu. 
    Using the Manual Control keys drive the antenna to the full 
extent of its travel in each direction. Confirm that the antenna 
actually moves in the required direction. Check that when a 
limit switch is reached the motor stops and the System Alarm 
indicator illuminates. 
  Note  Only one Manual Control key should be pressed at one time 
and it should be fully released before pressing another control 
key. 
    If a Dual Speed Motor Drive Cabinet is fitted check that the 
“FAST” key operates correctly. Pressing the “FAST” key 
when pressing a Manual Control key should latch fast drive in 
the required direction. Pressing any Manual Key when in 
latched Fast Drive should have no effect. Pressing the Fast 
key again should remove drive. 
Emergency Stop Check    Check the operation of the front panel Emergency Stop 
switch by pressing it when one or more motor’s is running.  
Ensure that the motor(s) stop and will not re-start until the 
Emergency Stop switch is released and the and the 
appropriate drive command re-instated. 