Specifications
Web GUI Monitoring & Control 
4.8.9  User-E 
This is identical to the User-1 mode except a 16 digit hex value is required for the ESW and a 14 
digit hex value is required for the injected ID. The even key is the same key as used for BISS-E. 
4.8.10  BISS Insertion Period 
This sets the frequency that the Program Association Table (PAT), Programme Map Table (PMT) 
and Conditional Access Table (CAT) will be inserted into the stream. The default is 200 ms and this 
value should be suitable in most circumstances. 
4.8.11  BISS Active Key 
When the BISS Mode is either Mode-E or ODD/EVEN-E or User-E then the BISS Active Key can be 
selected. This determines which key shall be used. 
4.8.12  BISS Status 
Table 4.3: BISS Status 
Property  Status  Description 
State 
Uninitialized  Error condition, BISS failure 
Idle : illegal in 
this mode 
BISS cannot be used in this mode 
Idle  BISS is turned off 
Configured  BISS is active, this will include BISS-0 Mode 
Extraction 
Active  SI extraction is active 
Inactive  no SI extraction 
Keys 
OK  Valid keys present, this should always be OK 
stream info  PAT not found  The PAT is not detected, critical failure 
Corrupted tables  At least one of the PMT listed in the PAT cannot be extracted or 
At least one of the PMT has a bad structure or a CRC error 
No CAT 
detected 
CAT is not found, this can be normal 
OK  Transport stream is OK 
processing 
Ciphering  The block cipher is engaged and ciphering 
Unciphering  The block cipher is engaged and deciphering 
None  The block cipher is not engaged 
PMT info 
Too many 
PMT(s) 
too many PMT(s) are received for the playout RAM (overflow) 
Incorrect PMT(s) 
A PMT cannot be modified to add/remove BISS SI (PIDs listed in the PMT 
would not be ciphered/deciphered) 
Missing PMT(s)  A PMT listed in the PAT could not be retrieved 
OK  All is OK 
4-26 SBM75e Series Modulator Installation and Operation Manual 