User manual
Advantech OEM commands
Advantech management solutions support extended OEM IPMI command sets,
based on the IPMI defined OEM/Group Network Function (NetFn) Codes 2Eh, 2Fh.
The first three data bytes of IPMI requests and responses under the OEM/Group
Network Function explicitly identify the OEM vendor that specifies the command
functionality. To be more precise, the vendor IANA Enterprise Number for the defining
body occupies the first three data bytes in a request, and the first three data bytes
following the completion code position in a response. Advantech’s IANA Enterprise
Number used for OEM commands is 002839h.
The BMC supports Advantech IPMI OEM commands listed in below table.
Command LUN NetFn CMD
Store Configuration Settings 00h 2Eh, 2Fh 40h
Read Configuration Settings 00h 2Eh, 2Fh 41h
Read Port 80 (BIOS POST Code) 00h 2Eh, 2Fh 80h
Clear CMOS 00h 2Eh, 2Fh 81h
Read MAC Address 00h 2Eh, 2Fh E2h
Load Default Configuration 00h 2Eh, 2Fh F2h
A.1 IPMItool raw command
To be able to use the Advantech OEM commands with the open source IPMItool,
users have to employ the “raw” command of IPMItool. Please find below command
structure details of the IPMItool raw command.
General raw request:
Response, if raw <netfn> is 2Eh (OEM/Group):
A.2 Configuration Setting OEM commands
The Read and Store Configuration OEM commands can be used to read and change
several important board settings. The following sub-chapters describe the needed
command details.
<IANA Enterprise Number> [data]
ipmitool raw <netfn> <cmd> [data]