39 SNMP-1000-B2 User Manual
Chapter 4 Programming SNMP-1000-B2
Command Device
Device
Code
Device
Sub-Item
Device
Subcode
Value(xxxx) Remark
w301xxxxxx 3 3V 30
Upper Limit 1 -15 0 15 0
Voltage value
in ASCII code,
max. 6 char-
acters, incl. "-
", "." ex.:
03.53-12.55-
13
w311xxxxxx 5V 31
w321xxxxxx -5V 32
w331xxxxxx 5VSB 33
w341xxxxxx 12V 34
w351xxxxxx -12V 35
w302xxxxxx 3 3V 30
Lower Limit 2 -15 0 15 0
w312xxxxxx 5V 31
w322xxxxxx -5V 32
w332xxxxxx 5VSB 33
w342xxxxxx 12V 34
w352xxxxxx -12V 35
w303x 3 3V 30
Alarm
Level
3
1 Not Used
w313x 5V 31 2 No Alarm
w323x -5V 32
3Criticalw333x 5VSB 33
w343x 12V 34
w353x -12V 35 4 Major
w304x 3 3V 30 5 Minor
w314x 5V 31
Event
Output
4
1None
w324x -5V 32 2 Power Off
w334x 5VSB 33 3 DO 0
w344x 12V 34 4 DO 1
w354x -12V 35
5DO 2
6DO 3