User`s manual
PCA-6186 User’s Manual 98
;-----------------------------------------------------------
Dec dx ; Set second as counting unit 
Mov al,0f5h
Out dx,al
Inc dx
In al,dx
And al,not 08h 
Out dx,al  
;-----------------------------------------------------------
Dec dx  ; Set timeout interval as 10 seconds and start counting
Mov al,0f6h
Out dx,al
Inc dx
Mov al,10
Out dx,al  
;-----------------------------------------------------------
Dec dx  ; lock W83627HF 
Mov al,0aah
Out dx,al
2. Enable watchdog timer and set 5 minutes as timeout interval
;-----------------------------------------------------------
Mov dx,2eh ; unlock W83627H
Mov al,87h
Out dx,al
Out dx,al  
;-----------------------------------------------------------
Mov al,07h ; Select registers of watchdog timer
Out dx,al
Inc dx
Mov al,08h
Out dx,al  