AWS-842TPB/SPB Industrial Workstation (Version B) with 10.
Copyright Notice This document is copyrighted, June 1998, by Advantech Co., Ltd. All rights are reserved. Advantech Co., Ltd. reserves the right to make improvements to the products described in this manual at any time without notice. No part of this manual may be reproduced, copied, translated, or transmitted in any form or by any means without the prior written permission of Advantech Co., Ltd. Information provided in this manual is intended to be accurate and reliable. However, Advantech Co., Ltd.
FCC Class A This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy. If not installed and used in accordance with this user's manual, it may cause harmful interference to radio communications.
Packing List Before you set up the AWS-842TPB/SPB, make sure that the following materials have been included with the package, and that this manual is in good condition. If anything is missing or damaged, contact your dealer immediately: • One AWS-842 Version B industrial workstation with 10.
Additional Information And Assistance 1. Visit the Advantech web sites at www.advantech.com or www.advantech.com.tw where you can find the latest information about the product. 2. Contact your distributor, sales representative, or Advantech's customer service center for technical support if you need additional assistance.
Safety Instructions 1. Read these safety instructions carefully. 2. Keep this User's Manual for later reference. 3. Disconnect this equipment from any AC outlet before cleaning. Use a damp cloth. Do not use liquid or spray detergents for cleaning. 4. For plug-in equipment, the power outlet socket must be located near the equipment and must be easily accessible. 5. Keep this equipment away from humidity. 6. Put this equipment on a reliable surface during installation.
Wichtige Sicherheishinweise 1. Bitte lesen sie Sich diese Hinweise sorgfältig durch. 2. Heben Sie diese Anleitung für den späteren Gebrauch auf. 3. Vor jedem Reinigen ist das Gerät vom Stromnetz zu trennen. Verwenden Sie Keine Flüssig-oder Aerosolreiniger. Am besten dient ein angefeuchtetes Tuch zur Reinigung. 4. Die NetzanschluBsteckdose soll nahe dem Gerät angebracht und leicht zugänglich sein. 5. Das Gerät ist vor Feuchtigkeit zu schützen. 6.
Contents Chapter 1 Introduction .......................................................1 1.1 1.2 1.3 1.4 1.5 1.6 Description ............................................................................... 2 Versatile backplane supply ....................................................... 2 Sealed-membrane tactile-response keypad ............................... 2 Accessible and secure control panel ......................................... 3 Specifications ................................................
Chapter 3 Macro Key Programming ...............................23 3.1 3.2 3.3 3.4 3.5 Introduction ........................................................................... 24 Macro Components ............................................................... 24 Macro keys .............................................................................. 24 Macro EEPROM ..................................................................... 24 Macro programming utility ...........................................
Appendix A Power Supply Specifications .....................41 A.1 A.2 A.3 260 Watt Power Supply ........................................................ 42 Specifications .......................................................................... 42 General features ...................................................................... 44 Environmental specifications .................................................. 44 International standards compliance ........................................
CHAPTER Introduction • Description • Specifications • Dimensions • Complete functionality • Front accessible CD-ROM • Front control panel 1
1.1 Description The AWS-842 series workstations take advantage of modern flat-panel displays for minimum size. They can be ordered with either a color TFT LCD or DSTN LCD display. The AWS-842 offers two types of passive backplane, 3 PCI / 4 ISA / 1 CPU (PCA-6108P3) and 8 ISA (PCA-6108) slots, 260 watt power supply, data-entry/function-key keypads, a slim floppy drive, and two spaces for a hard drive and a slim CD-ROM.
Note: To use the keyboard and keypad simultaneously, you must first connect the keyboard connector on the backplane to the keyboard connector on the CPU card, and then connect the external keyboard jack to another keyboard jack located next to the power supply. If you connect the keyboard to the 5-pin DIN connector on the CPU card, neither the keyboard nor the keypad will work. The keyboard must be connected to the jack behind the front door.
1.2 Specifications General • Front panel: Aluminum, meets NEMA 4 or IP 65 • Disk drive housing: Supports one slim 3.5" FDD, one 3.
• Controller: RS-232 interface • Power consumption: +5 V @ 200 mA • Software driver: Supports MS-DOS, Windows 3.1, Windows 95, Windows NT and OS/2 Passive backplane • PCA-6108P3: 4 ISA, 3 PCI, 1 CPU slot • PCA-6108C: 8 ISA slot Power supply options AC input 260 W (standard offer) • Input: 85 ~ 130 VAC or 180 ~ 260 VAC, switchable • Output: +5 V @ 25 A; +12 V @ 9 A; -5 V @ 0.5 A; -12 V @ 2.
LCD display Model AWS-842T AWS-842S 10.4" TFT color 10.4" DSTN 640 x 480 640 x 480 256 K colors 4096 colors 0.33 x 0.33 0.33 x 0.33 Luminance (cd/m2) 250 130 Viewing angle 90° 90° Temperature 0 ~ 50° C 0 ~ 45° C VR controller Brightness Contrast LCD MTBF 50,000 hours 50,000 hours Backlight MTBF 20,000 hours 25,000 hours PCA-6653-842T PCA-6653-842S Display type Max. resolution Max.
1.3 Dimensions Cutout dimensions: 445 mm x 240 mm Unit: mm Before you rackmount or panelmount the AWS-842TPB/SPB, use the following diagram to verify that the mounting screws correspond with the holes in your panel/rack.
1.4 Complete Functionality Keyboard translator 4 ISA / 3 PCI / 1 CPU slot (or 8 ISA) passive backplane (Also accommodates a ``Baby`` AT motherboard) VGA card (PCA-6653 included) Cooling fan with removable filter Shielded 10.
1.
1.
CHAPTER 2 System Setup • General • Opening the top panel and rear panel • Adding cards • Installing optional drives • Panel mounting • Rack mounting
2.1 General Your AWS-842TPB/SPB is easy to use. All you have to do is remove its cover, install your CPU card, display adapter card, an optional hard disk drive, and whatever additional I/O cards that your application requires, and you are ready to mount your workstation into a 19-inch rack or panel. Warning! Do not begin your installation until you are sure there is no power flowing within the AWS-842TPB/SPB. It must be switched off and unplugged.
2.2 Opening The Top Panel And Rear Panel Remove the eight screws from the top panel and then open the top cover. (See Fig. 2-1.) After removing the top cover, you can detach the six screws from the rear panel and open the rear panel. (See Fig. 2-2.
Figure 2-2: Opening the rear panel 14 AWS-842TPB/SPB User's Manual
2.3 Adding Cards The PCI passive backplane accepts both PCI-bus and ISA-bus CPU and I/O cards. We recommend all-in-one cards. They are durable, and save valuable slot space by bundling a CPU card with hard disk and floppy disk controllers, as well as serial and parallel ports. Open the top panel (see Section 2.2) and then slowly slide the card in and carefully press it into the backplane socket. Secure it with a screw to the top mounting bar. (See Fig. 2-3). Connect the wires.
2.4 Installing Optional Drives The AWS-842TPB/SPB provides space for three drives (one slim floppy disk drive, one hard disk drive and one slim CD-ROM drive) underneath the case. A front-facing floppy drive has already been installed. You can access it from the FDD dust-resistant door panel. If you wish, you can add a 3.5" hard disk drive or a slim CD-ROM drive above the front-facing floppy drive.
Figure 2-5: Installing an FDD Chapter 2 System Setup 17
Figure 2-6: Installing an HDD 18 AWS-842TPB/SPB User's Manual
Figure 2-7: Installing a CD-ROM Chapter 2 System Setup 19
2.5 Panel Mounting The AWS-842TPB/SPB will stand on a shelf or a table, and it may be mounted within a panel. Dimensions for the case, the mounting flange, and the mounting bolts are shown in Fig. 1-1. Once you have added your cards, drives, and other equipment, you should switch on the AWS-842TPB/SPB to confirm that it works. Then set the case within your panel aperture so that your screw holes line up with the mounting bolts on the flange of the AWS-842TPB/SPB. Secure the bolts to the panel.
2.6 Rack Mounting The AWS-842TPB/SPB can also be mounted in a 19" rack. Make sure that all additional equipment has been installed correctly. Also make sure that all cabling (such as the monitor signal cable, the keyboard cable and the monitor power cable) has been reattached. Attach the rack to the case using screws on both sides of the case.
22 AWS-842TPB/SPB User's Manual
CHAPTER Macro Key Programming • Introduction • Macro components • Syntax • How to use SFED842.
3.1 Introduction Our workstations are equipped with programmable function keys (macro keys) that greatly enhance the operator interface. Macros, far more powerful than batch files, automate the most commonly used input sequences. They extended their functional reach to within application programs. 3.2 Macro Components The following article explains how to use and program the function keys.
3.3 Syntax Macro definitions consist of ASCII characters or character codes for special characters such as ALT, ENTER, SHIFT, F1, SF2, and so on. These codes are predefined, and SFED842.COM will display them on the screen for you. They are easily recognizable, appearing between the square brackets ‘[‘ and ‘]’. For example : ALT represents [26] ENTER represents [33] In your macro script, you can enter ordinary text (ASCII characters) or the code(s) of the required special character(s).
Please refer to the following examples: ALT-X represents [26]X[90] or [26]x[90]. ALT-F1 represents [26][44][90] SHIFT-X represents [27]X[90] SHIFT-F1 represents [27][44][90] CTRL-X represents [28]X[90] CTRL-F represents [28][44][90] CTRL-ALT-DEL represents [28][26][41][90] (reboot) CTRL-ALT-A represents [28][26]A[90] CTRL-SHIFT-1 represents [28][27]1[90] Another useful function is the DELAY instruction. You can instruct the macro program to wait before executing the next keystroke. SFED842.
3.4 How To Use SFED842.COM First, copy all the files to your hard disk and/or make a backup disk. When starting the macro editor, you will have to specify either an existing macro script file or a new macro script file. Here we will create a new file by typing SFED842 NEWKEY.TXT [ENTER]. The following screen will appear: Advantech Workstation Special Function Key Edit Program Rev.
3.5 Examples We will explain all macro functions that you can find in the EX842.TXT macro script file. After typing SFED842 EX842.TXT [ENTER], the following editor screen will appear: Advantech Workstation Special Function Key Edit Program Rev.
SF1 = CD\TOOL[33] SFED842 EXAMPLE.TXT[33] This macro changes to the TOOL directory, then starts up SFED842.COM with EXAMPLE.TXT. SF2 = COPY C:\CONFIG.EMM C:\CONFlG.SYS[33]Y[33][85][79] The configuration information is changed by copying CONFIG.EMM to CONFIG.SYS. After a delay of 5 seconds, [85], the macro, invokes macro function key SF10, [79], which was defined to reset the system. SF4 = C:\WP51\WP[33][86][27][4D][90]REPORT.
30 AWS-842TPB/SPB User's Manual
CHAPTER 4 Maintenance • Detaching the backplane and bracket • Power supply • LCD maintenance • Keyboard translator • LED board • Touchscreen controller
4.1 Detaching The Backplane And Bracket Before detaching the bracket, you must open the top and rear covers (see Figure 2-1). Remove the card from the backplane and detach the backplane. If you want to repair and upgrade your peripherals (for example, the membrane keypad controller or the backlight of the LCD), you must first pull out the bracket.
4.2 Power Supply To repair or upgrade your power supply, first detach and remove the top and rear covers. Unscrew the four screws on the side panel (see Fig. 4-2), and disconnect all DC output connectors and the AC line. Warning: Shut off all power to the AWS-842TPB/SPB before you commence to repair the power supply. Switch off the power and unplug the unit. For detailed power supply specifications, refer to Appendix A.
4.3 LCD Maintenance In the normal working life of the AWS-842TPB/SPB, you may have to replace the inverter, LCD or LCD backlight. Follow these instructions: 1. Open the top and rear cover. (See Fig. 2-1.) 2. Disconnect the cable from the LCD controller and LCD. 3. Pull out the bracket which is located below the backplane. 4. Detach the bracket behind the front panel. 5. Disconnect the cables of the inverter, and the cables of the touchscreen controller (if applicable).
Figure 4-3: Installing the LCD backlight Chapter 4 Maintenance 35
4.4 Keyboard Translator The keyboard translator is an interface which switches the signal from the membrane keypad to the standard AT keyboard. There are six connectors on the board. On top of the board, there are two connectors linking two flat cables with the larger membrane keypad (as shown in Fig. 4-5). On the side of the board, there are four connectors. For connection details, refer to Fig. 4-5. When servicing the keyboard translator: 1. Switch off the power, and detach the main power cord. 2.
(A) (B) (F) Keyboard translator (C) to (C') CPU card (O) (A) Input from external keyboard (A) (B) Input from external keyboard (B) (F) Input from function keypad (F1, F2, ...) (O) Input from operation keypad (1, 2, 3, ...
Figure 4-5: Keyboard translator input/output (detailed schematic) 38 AWS-842TPB/SPB User's Manual
4.5 LED Board It is very unlikely that the LED board will have to be replaced. There are two indicators in the LED board: HDD and power. You do not need to remove the backplane and bracket to replace the LED board. Simply detach the bays for the FDD, HDD and slim CD-ROM drive, and then unscrew the three screws fixed into the panel. Before removing the LED board, carefully detach the cables by pulling them down. 4.6 Touchscreen Controller To service or replace the touchscreen controller: 1.
40 AWS-842TPB/SPB User's Manual
APPENDIX Power Supply Specifications • 260 watt power supply • -48 VDC power supply • 24 VDC power supply A
A.1 260 Watt Power Supply The AWS-842TPB/SPB off-line switching power supply is ideal for use in workstations. It has been designed to meet UL, CSA and TUV safety standards. It has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
Output power: Total DC continuous power does not exceed 260 W. Total DC peak power does not exceed 280 W. When the input voltage is less than 100 VAC, total DC continuous power should not exceed 220 W. Ripple and noise: Peak to peak ripple and noise for +12 V is less than 140 mV. Peak to peak ripple and noise for other outputs is less than 1% of each output’s respective voltage at the rated load (namely 115/230 VAC).
Hold up time: 14 ms typical @ 115 VAC This figure was obtained from the last AC line charging pulse to the point where +5 V dropped down to +4.75 V. Power good signal: When the power is turned on, the power good signal will activate 100 to 500 ms after all output DC voltages are operating within thier respective regulation limits. Power fail signal: This will activate at least 0.5 ms before any of the output voltages fall below their respective regulation limits.
International standards compliance Safety: UL 1950, CSA 22.2 No.
A.2 -48 VDC Power Supply The following specifications describe the physical and electrical characteristics of a 310 W, four output, DC to DC switching power supply housed in a standard size PS/2 casing. Specifications 46 Input voltage: -38 ~ -58 VDC (continuous operation) -48 VDC (normal operation) Input current: 10 A max. @ -48 VDC input Inrush current: 5 A max. @ -48 VDC input Efficiency: 70% min.
Output characteristics: Table A-3: -48 VDC power supply output characteristics Total regulation tolerance Loading current Output voltage Noise plus ripple Min. Max. Surge Max. Min. Max. +5 VDC 2A 25 A 30 A +3% -3% 50 mV p-p +12 VDC 0A 10 A 12 A +3% -3% 120 mV p-p -5 V DC 0.0 A 1.0 A - +5% -5% 50 mV p-p -12 V DC 0.0 A 5A - +3% -3% 120 mV p-p Note 1: Total regulation tolerance includes temperature change, warmup drift and dynamic load.
Power good and power fail signals (optional): When the power is turned on, the power good signal will activate 100 to 500 ms after all output DC voltages are operating within their respective regulation limits. The power fail signal will activate at least 1 ms before the +5 V output voltage falls below its regulation limit. Short circuit protection: A short circuit placed on any output to ground is shut down.
Reset time: When the power supply has automatically shut down, and the short circuit, over-current and/or over-voltage conditions have ceased to exist, power will be automatically recycled to restart the power supply within 3 seconds of such return to normal conditions. No load start: When the power supply is switched on but with no load connected, the power supply does not get damaged, and it is still completely safe for users.
DC output wire list All DC output cables use UL 1007 type wires.
A.3 24 VDC Power Supply This is a DC to DC switching mode power supply with a 24 VDC input. Specifications Input voltage: +19 ~ +32 VDC (normal operation) Input current: 16 A max. @ +24 VDC input Inrush current: 10 A max. @ +24 VDC input Output load range: Table A-5: 24 VDC power supply output load range Output No. 1 Output +5 V Min. load 1.0 A Rated load 25 A Peak load 30 A Voltage accuracy 4.90 ~ 5.10 V 2 +12 V 0A 10 A 12 A 11.28 ~ 12.72 V 3 -12 V 0A 1A 2A -11.40 ~ -12.
Line regulation: The output line regulation for each output is less than ±1%, when measured at each output’s respective rated load and under ±10% changing input voltage conditions. Load regulation: The values for each of the following output numbers were obtained by changing each output load ±40% from the 60% rated load, whilst simultaneously keeping all other outputs at 60% of their respective rated loads. Table A-6: 24 VDC power supply load regulation Output No.
General features Efficiency: 65% typical when measured at nominal input and rated load. Input protection: Protection against wrong polarity if the +24 V input voltage is mistakenly reversed. Output protection: If for some reason the power supply fails to control itself, the built-in over-voltage protection circuit will shut down the outputs to prevent damage to external circuits. The trip point of the crowbar circuit is approximately 5.7 ~ 7.0 V.
54 AWS-842TPB/SPB User’s Manual
APPENDIX Touchscreen Driver Installation • Introduction • Windows 95 • Windows 3.
B.1 Introduction Before you attempt installation of the touchscreen driver, you should carefully read the instructions in the relevant "read me" file stored in the installation CD-ROM. The file path for the instructions in the CD-ROM is: D:\monmouse\ This is where you will find instructions for Win 95, DOS 3.1, Win NT, and OS/2. 56 Note 1: The touchscreen driver must be installed from the CD-ROM supplied. The CD-ROM drive is designated as "D" throughout this chapter.
B.2 Windows 95 1. a. Insert the ELO driver CD disc. b. Select "Start", "Run". c. Type the path eg. "d:\monmouse\ win95\setup.exe". 2. a. Press the "Next" button. 3. a. Set the path of the directory. 4. a. Choose "Typical".
5. a. Click "OK" to upgrade the driver. 6. a. Click "OK" to make a backup copy. 7. a. Click "OK" to start the wizard. 8. a. Click "OK" to accept the default.
9. a. Click "OK" but do not reboot. 10. a. Exit and reboot. b. Select "Start", "Settings", "Control Panel". c. Double click "Elo touchscreen". 11. a. Click "Calibrate".
B.3 Windows 3.1 and DOS 1. a. Execute "install.exe" in the DOS environment. b. Press to continue. 2. a. Type the installing path of the ELO directory. 3. a. Select "Dos.." or "Windows..". Windows 3.1 a. Follow the on-screen instructions. 4. DOS Windows 3.1 5. 60 a. Choose the "Serial" item.
6. COM1 COM2 COM3 COM4 a. Select the "COM1" item. COM2 COM3 COM4 a. Press to install. 7. Windows 3.1 a. Type the Windows 3.1 path. 8. DOS Windows 3.1 9. 10. a. Add "nomouse.com" to "autoexec.bat" if there is no mouse driver installed. b. If yes, the window disappears. a. Press to continue.
11. a. Choose "Overwrite...". Windows 3.1 a. Press to continue. 12. DOS 13. Windows 3.1 a. Choose "Overwrite...". Windows 3.1 14. a. Type "go" to run calibration. b. Touch fix points to calibrate.
B.4 Windows NT 1. a. Insert the ELO driver CD disc. b. Select "Start", "Run". c. Type the path. eg. "d:\monmouse\ winnt\setup.exe". 2. a. Press the "Next" button. 3. a. Set the directory path. 4. a. Choose "Typical".
5. a. Press "OK" to accept the default. 6. a. Click "OK". 7. a. Exit and reboot. b. Select "Start", "Settings", "Control Panel". c. Double click "Elo touchscreen". 8. a. Click "Calibrate". 9. a. Test the calibration.
B.5 OS/2 (MonitorMouse) First, be sure OS/2 is installed and operating properly with your mouse. We suggest that you prepare OS/2 installation disks or a bootable DOS disk. By doing so, you can easily reboot from such disks should an improper setting in CONFIG.SYS cause the system to not work. Five steps are required when installing MonitorMouse for OS/2: Step 1 - Configure your Controller Step 2 - Copy the Software Step 3 - Modify CONFIG.
STEP 2 - COPY THE SOFTWARE The following files are on the MonitorMouse for OS/2 disk: !READ.ME! Text file containing any additions or changes made after this manual was printed. MONMOU01.SYS Touchscreen driver for serial touchscreen controllers on PC bus systems. MONMOU02.SYS Touchscreen driver for serial touchscreen controllers on Micro Channel systems. MONMOU03.SYS Touchscreen driver for PC bus and Micro Channel touchscreen controllers. ELOCAL2.
International versions of the touchscreen control panel software program are included in subdirectories on the MonitorMouse for OS/2 disk. Replace ELOCAL2.DLL and ELOCAL2.HLP on your hard disk with the versions from the appropriate subdirectory. STEP 3 - MODIFY CONFIG.SYS MonitorMouse for OS/2 is installed by commands in CONFIG.SYS. Use your system editor to make these changes. In general, the changes are as follows: 1. Comment-out the existing DEVICE command(s) for your mouse. 2.
is: the number of the COM port where the serial output of the touchscreen controller is connected. matches the switch or jumper settings on the controller. Example MonitorMouse for OS/2 DEVICE command: Device=c:\elo\monmou01.sys 2210,1,9600 No Mouse If you do not wish to have a mouse connected, change the “stype=elomou$” flag to “type=elomou$” on the DEVICE=MOUSE.SYS command.
STEP 4 - INSTALL THE TOUCHSCREEN CONTROL PANEL The touchscreen control panel software program, ELOCAL2.EXE, is a presentation manager application for calibrating the touchscreen and setting various options. Add the \ELO\ELOCAL2.EXE program to the System Setup folder and label the icon “Touchscreen”. This is accomplished as follows: 1. Open the OS/2 System folder, then System Setup. 2. Open the Templates folder. 3. Drag the Program template with the right mouse button into the System Setup folder.
70 AWS-842TPB/SPB User's Manual