User manual
PCE-7210 User Manual 94
9.4 IPMI OEM command lists
In addition to the above list of IPMI commands, the following OEM com-
mands will be supported.
Table 9.2: OEM Commands list
Net Function = 0x2E, LUN = 0
Code Command Request, Response Data Description
05h Set System 
GUID
Request: 
Byte 1:16 – System GUID 
Response: 
Byte 1 — Completion code.
This command is 
used to set the 
system GUID. 
The GUID can be 
retrieved using a 
standard IPMI 
command.
0Dh Reset to 
Defaults
Request: 
Reset module ID 
Byte 1[7:0] 
1 = OEM module 
2 = LAN module 
3 = User Info module 
4 = Serial module 
5 = SOL module 
6 = PEF module 
7 = Firewall module 
8 = System Information 
0xFF = all modules 
Byte 2:4 
Reserved. 
Response: 
Byte 1 
Status of Reset to Default. If fail, 
this value indicate the last fail 
module and the reset process 
stops. 
[7:0] 
0 = success 
1 = fail in OEM module 
2 = fail in LAN module 
3 = fail in User Info module 
4 = fail in Serial module 
5 = fail in SOL module 
6 = fail in PEF module 
7 = fail in Firewall module 
8 = fail in System Information 
This command 
resets the BMC 
configuration to 
default values. 