Specifications
Chapter 1 Introduction 3
• Provides 2000 V
DC
surge protection (PCL-846B/847B)
• Space reserved for termination resistors
• Supports 2 wire or 4 wire operation
• Supports Tx, Rx, RTS, and CTS signals
• Automatic RS-485 data flow control or RTS control
• RS-422 on Auto/RTS/On mode
Specifications
• Ports: 4
• UART: 4 x 16C550 with 16-byte FIFO
• Speed: 50 ~ 921.6 Kbps
• Parity: none, even, odd
• Signal support:
TxD+, TxD-, RxD+, RxD-, CTS+, CTS-, RTS+, RTS- and GND
• I/O address: From 200H to 3F8H
• IRQ: 3, 4, 5, 6, 7, 9, 10, 11, 12 or 15
• Isolation voltage: 1000 V
DC
(PCL-846A/846B only)
• Surge protection: 2000 V
DC
(PCL-846B/847B)
• Power consumption: PCL-847; +5 V @ 460 mA typical, 570 mA max.
PCL-846; +5 V @ 970 mA typical, 1200 mA max.
• Cables: 30-cm male DB-37 to four male DB-9 (DTE)
• Operating temperature: 0 ~ 60°
C (32 ~ 140°
F) (refer to IEC-68-1.2.3)
• Storage temperature: -25 ~ 80°
C (-13 ~ 176°
F)
• Dimensions: 185 mm x 100 mm (7.3" x 3.9")
• MTBF: PCL-847A 126630 hrs at 25°
C Ground, Fixed environment
PCL-847B 120992 hrs at 25°
C Ground, Fixed environment
PCL-846A 105014 hrs at 25°
C Ground, Fixed environment
PCL-846B 101107 hrs at 25°
C Ground, Fixed environment
• For technical support and service please visit our support website at
http://support.advantech.com
and visit the "Industrial Automation Support" and "FAQ" sections.