Description of BMX P34 1000/2000/20102 processors
BMX P34 1000/2000/20102 Standard and Performance single-format processors
have the following on the front panel:
1 Safety screw for locking the module in its slot (marked 0) in the rack
2 A display block comprising 5 or 7 LEDs, depending on the model:
RUN LED (green): processor in operation (program execution)
ERR LED (red): processor or system fault
I/O LED (red): I/O module fault
SER COM LED (yellow): activity on the Modbus serial link
CARD ERR LED (red): memory card missing or faulty
CAN RUN LED (green): integrated CANopen bus operational (BMX P34 20102
model only)
CAN ERR LED (red): integrated CANopen bus fault ((BMX P34 20102 model only)
3 A mini B USB connector for a programming terminal (or a Magelis XBT GT/GK/Magelis XBT GT/GK/
GTW, GTW HMI, STU/STO HMI terminal (1))
4 A slot equipped with its Flash memory card for backing up the application (an
LED, located above this slot, indicates recognition of or access to the memory
card)
5 An RJ45 connector for the Modbus serial link or Character mode link
(RS 232C/RS 485, 2-wire, non-isolated)
With, in addition, for model
BMX P34 20102:
6 A 9-way SUB-D connector for the integrated CANopen master bus
Description of BMX P34 2020/20302 processors with
integrated Ethernet Modbus/TCP port
BMX P34 2020/20302 Performance single-format processors have the following on
the front panel:
1 Safety screw for locking the module in its slot (marked 0) in the rack
2 A display block comprising 8 or 10 LEDs, depending on the model:
RUN LED (green): processor in operation (program execution)
ERR LED (red): processor or system fault
I/O LED (red): I/O module fault
SER COM LED (yellow): activity on the Modbus serial link
CARD ERR LED (red): memory card missing or faulty
ETH ACT LED (green): activity on the Ethernet Modbus/TCP network
ETH STS LED (green): Ethernet Modbus/TCP network status
ETH 100 LED (red): Ethernet Modbus/TCP data rate (10 or 100 Mbps)
CAN RUN LED (green): integrated CANopen bus operational ((BMX P34 20302
model only)
CAN ERR LED (red): integrated CANopen bus fault ((BMX P34 20302 model only)
3 A mini B USB connector for a programming terminal (or a Magelis XBT GT/GK/Magelis XBT GT/GK/
GTW, GTW HMI and STU/STO HMI terminal (1))
4 A slot equipped with its Flash memory card for backing up the application (an
LED, located above this slot, indicates recognition of or access to the memory
card)
5 An RJ45 connector for connection to the 10BASE-T/100BASE-TX Ethernet
Modbus/TCP network
With, in addition, depending on the model:
6 BMX P 34 2020 processor: an RJ45 connector for the Modbus serial link or
Character mode link (RS 232C/RS 485, 2-wire, non-isolated)
7 BMX P 34 20302 processor: a 9-way SUB-D connector for the integrated
CANopen master bus
On the back panel: 2 rotary switches for selecting the IP address assignment
method for the module.
USB terminal port
The USB port
3 offering a useful data rate of 12 Mbps, is compatible with the
Unity Pro programming software, the OPC Factory Server (OFS) and
Magelis XBT GT/GK/GTW, GTW HMI and STU/STO HMI terminals GTW HMI and STU/STO HMI terminals (1).
All
BMX P34 processors can be connected to a USB bus comprising several
peripheral devices. However:
Only one processor must be connected to the USB bus
No device on the USB bus can be controlled by the PLC (modem, printer)
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
b
b
BMX P34 20102
BMX P34 1000/2000
BMX P34 20302
7
2
3
5
1
4
5
2
3
1
4
6
2
3
5
1
4
BMX P34 2020
6
2
3
5
1
4
BMX P34 20102
BMX P34 1000/2000
BMX P34 20302
7
2
3
5
1
4
5
2
3
1
4
6
2
3
5
1
4
BMX P34 2020
6
2
3
5
1
4
Description
(1) Magelis XBT GT/GK/GTW, GTW HMI and STU/STO HMIXBT GT/GK/GTW, GTW HMI and STU/STO HMI
graphic terminals with USB port and Vijeo Designer with USB port and Vijeo Designer
configuration software version u 4.5. Please consult our
“Human Machine Interfaces” catalogue
Modicon M340 automation
platform
Processor modules
1
2
3
4
5
6
7
8
9
10