Technical information

2
1
3
4
5
6
7
8
9
10
2
1
3
4
5
6
7
8
9
10
Selection guide (continued)
Ethernet network
Cabling system
ConneXium unmanaged switches
Type of device Unmanaged switches, copper twisted pair
Interfaces Copper cable ports Number and type 5 x 10BASE-T/100BASE-TX ports 8 x 10BASE-T/100BASE-TX ports
Shielded connectors M12 (type D) RJ45
Medium Shielded twisted pair, category CAT 5E
Total length of pair 100 m
Fibre optic ports Number and type
Connectors
Medium
Length of optical fibre 50/125 µm
62.2/125 µm
Optical fibre
attenuation analysis
50/125 µm fibre
62.2/125 µm fibre
Ethernet services Storage and re-routing of received data,
auto MDI/MDX, automatic negotiation of
10/100 Mbps and duplex mode
(on all ports)
Topology Number of switches Cascaded Unlimited
Redundant in a ring
Redundancy P1 and P2 redundant power supplies
Power supply Voltage 24 V c (18…32), safety extra low voltage (SELV)
Consumption 100 mA max. 125 mA (290 mA max.)
Removable terminal block 5-way, M12 (type A, male) 5-way
Operating temperature 0…+ 60°C
Relative humidity 10…95% non condensing
Degree of protection
IP 67 IP 20
Dimensions W x H x D 60 x 126 x 31 mm 47 x 135 x 111 mm
Mounting On symmetrical DIN rail, 35 mm wide
Weight 0.210 kg 0.230 kg
Conformity to standards cUL 508 and CSA 22.2 No. 142 cUL 60950, UL 508 and CSA 22.2 No. 142,
UL 1604 and CSA 22.2 No. 213 class 1
division 2, e, GL, C-Tick
LED indicators Power supply, link status, data rate P1 and P2 power supplies, Ethernet link/port
status
Alarm relay Power supply fault, Ethernet network fault or
communication port fault (volt-free contact
1 A max. at 24 V c)
Reference
TCS ESU 051F0 499 NES 181 00