User manual
VITA-350E User Manual 34
the data format is text. The data format could be changed by users. The
default type is Customized Platform.
“ID number” edit in “Platform Options” group : Define the ID number of
VITA-350E. This text will be sent to server when the format included the
string <ID>.
“ID name” edit in “Platform Options” group : Define the ID name of
VITA-350E. This text will be sent to server when the format included the
string <TYPE>.
“Set” button in “Platform Options” group : Set the ID number and Name
to VITA-350E.
“Get” button in “Platform Options” group : Get the ID number and Name
from VITA-350E.
“Voltage Source” static text in “Voltage Source” group : Show the Volt-
age Source. The value should be “12V” or “24V”.
“Get” button in “Voltage Source” group : Get the Voltage Source from
VITA-350E.
“First IP Address” edit text in “Server Options” group : Define the first
server IP address. The VITA-350E will send data to the first server peri-
odically.
“First IP Port Number” edit text in “Server Options” group : Define the
first server socket port number.
“Second IP Address” edit text in “Server Options” group : Define the sec-
ond server IP address. The VITA-350E will send data to the senond
server when the first server is unconnected.
“Second IP Port Number” edit text in “Server Options” group : Define the
second server socket port number.
“Send Format” edit text in “Server Options” group : Define the format of
data sent to the server. The format descriptions are documented in Chap-
ter 3. The default format is $,<TYPE>,<ID>,<FIX>,<DDM-
MYY>,<HHMMSS>,<RMC(4)><RMC(3)>,<RMC(6)><RMC(5)>,<SP
EED>,<ANGLE>,0,#<CR><LF>
“Interval Time” edit text in “Server Options” group : Define the interval
seconds between dada packets. The default value is 30 seconds.
“Re-Send Head String” edit text in “Server Options” group : Define the
re-send data head string. When the server is disconnected or GPRS is