INSTALLATION REQUIREMENTS 
In order to maintain the independent approval of this unit, it must be installed such that clearance and 
creepage distances shown in the table below are maintained between 
The unit and any other assemblies that either use or generate a voltage shown. 
Clearance 
Xmm 
Creepage 
Ymm 
Voltage used or Generated 
by Host or other Cards 
2.0  2.4 (3.8)  Up to 50V rms or Vdc 
2.6  3.0 (4.8)  Up to 125V rms or Vdc 
4.0  5.0 (8.0)  Up to 250V rms or Vdc 
4.0  6.4 (10.0)  Up to 300V rms or Vdc 
Note : 
The Creepage distance is the shortest path between two conductive parts , or between a conductive 
part and the surface of the enclosure measured along the surface of the insulation 
The Clearance distance is the shortest distance between two conductive parts or between a 
conductive part and the enclosure surface of the equipment measured through air. 
The larger distance, shown in brackets, applies where the environment within the host is subject to 
conductive or dry non-conductive pollution which could become conductive due to condensation. 
In order to avoid any doubt, with regards to ensuring the AV Unit approval status is maintained, It is 
recommended that the unit is mounted in the main security panel in 
such a way that no control cards, expansion cards, power supplies etc. are within 
10mm of its outer limits (see Fig 4) 
Fig 4 
Important :   Where installation of the unit is required in a host which uses or generates voltages 
greater than 300V rms or d.c., advice from a competent telecommunications safety 
engineer must be obtained before installation. 