User's Manual
ADD-INS-PE3LR-CARE-ENG-31 Subject to change without noce
ADVEEZ, Bat MEAS - Impasse Jeanne Benozzi CS 83163 email: contact@adveez.com
31027 Toulouse Cedex 3 FRANCE Phoenix, AZ USA
+33(0)582082193 +1 602-549-7898
12
www.adveez.com
PE3LR-E located on the entrance
ZONE 1
ZONE 2
Sensing movement direcon via PE3LR-C door controller
Drawing below shows 2 separated zones, each being ed with 1 external reader close
to entrance and 1 controller/internal reader inside.
Door controller’s jumper J1 is acvated so that reader funcon gets acvated.
Door controller’s jumper J4 is deacvated so that access control is not acve on exit.
If card bearer wants to enter zone 1 with authorized card, his card is detected while
Filtering misdetecons inside the secured zone
Inhibing the detecon in a given area
Door controller’s dipswitch J1 is acvated so that reading funcon is acve.
A switch contact of exit request is connected to the Block 4. The dipswitch J4 of door
controller is deacvated to disable the access control in exit.
If card bearer being situated in zone 1 with authorized card wishes to pass the door
(controlled door) of the zone without going out, his card is detected in the intersecon
between green and orange detecon zones. The controller/internal reader will then
idenfy the passage of PE3LR-E reader in the internal detecon zone avoiding to unlock
the access.
Posioning readers of two dierent accesses
Two dierent detecon ranges can be congured on PE3LR-C
The detecon range in short distance (dipswitch J1 or J2 deacvated) is 1.5 m.
The detecon range in long distance (dipswitch J1 or J2 acvated) is 3 m.
PE3LR-C controller
Located in the zone to be secured
Access Control Systems / Wander monitoring