Specifications
Table Of Contents

ADVR.010.00.00.000 РЭ. Sheet 11 of 26
With the view to energy saving , the indicator stops glowing 20 seconds after last
pressing of any knob, while this LED#1 or LED#2 is :
- lightning constantly if the heater is activated;
- blinking rarely (1 time per 1,5 second) if the heater is not activated;
- blinking while fault (1 time per second);
- blinking frequently (5 times per second) while deactivation of the heater (while
purging)
To restart the indication there’s need to press any knob.
7.2 Succession of work with the control panel
7.2.1 Operation mode set up.
Before heater activation there’s need to select operation mode. Pressing knob with
the arrow “
A” select operation mode of the heater according to desired power or
temperature. According to the choice the LED#1 orLED#2 is lightning. After selecting
the mode “according temperature” there’s need to press knob with the arrow “
B” and
choose the sensor, according which the temperature of the heater will be controlled.
7.2.2 Activation and setting the power or temperature.
After mode selection there’s need to press the knob “O”, while this the heater will
start working and there’s information on the indicator- the power mode or
temperature mode according to your choice.(see fig. 7.3 or 7.4)
1818