Specifications

ADVR.010.00.00.000 РЭ. Sheet 12 of 26
If power mode is selected, pressing knobs with arrows “
A” (decreasing),
B”(increasing) – you can set up the necessary power (see fig. 7.3)which can be set
within 1 to 3 kWt. The indicator shows the scale according which the power is set up.
If temperature mode is selected , pressing knobs with arrows “
A” (decreasing),
B”(increasing) – you can set up the necessary temperature (see fig. 7.4). The
temperature is set within 15° to 30°C. You can see the figures on the indicator.
Attention!
1. The heater Operation mode (according to power or temperature) is saved
until new set up.
2. If cabin temperature sensor circuits are disconnected heater will go
working on middle power Operation mode.
3.While heater activation without setting operation modes it is necessary to
press the knob “O” one time if the indicator is lightning, and 2 times if the
indicator is not lightning.
7.2.3 Heater deactivation.
To deactivate the heater press the knob “O”. While this the heater is in switching
off mode, that means that the combustion process in combustion chamber is stopped
and the process of purging is started. According to the mode the indicator will show
information(for example) (see pictures 7.5 or 7.6), the LED#1 or LED#2 will be
blinking frequently until the process of purging is stopped.
2525
Picture 4.5-Purge Picture 7.6- Purge
Attention!
It is forbidden to switch off electric power supply before purge cycle is
finished.