05 Flame indicator failure Check the flame indicator
circuit for disconnection
fault with sensor
disconnected of its plate.
Resistance between
contacts should not
exceed 10 Ohm. Replace
the indicator if it is not
operational.
08 Flame failure Check the fuel level and
fuel supply system. Check
combustion air system
and the exhaust pipe line.
If the heater can be
started, check fuel pump
and replace if necessary.
09 Heating plug failure Check the plug and
replace if necessary.
10 Air pump motor failure Check the wiring of the
air pump, replace motor
if necessary.
12 Shutdown, voltage boost Check the battery,
regulator and power
supply wiring. The
voltage between 1 contact
and 2 contact of connector
XP13 (see connection
layout picture 4.1) should
not exceed 16V
13 No further activation attempt is
possible
If possible quantity of
activation attempts is
used, check the heating
plug, fuel level and fuel
supply system. Check
combustion air system
and exhaust pipe line.
15 Shutdown, low voltage Check the battery,
regulator and power
supply wiring. The
voltage between 1 contact
and 2 contact of connector
XP13 (see connection
layout picture 4.1) should
not exceed 10.5V