16 Ventilation period takes longer
than usual
The heater is not cooled
sufficiently during the
purge. Check the
combustion air supply
system and exhaust pipe
line. Check the flame
indicator and replace if
necessary.
17 Fuel pump failure Check fuel pump wiring
for short-circuit fault or
disconnection fault.
Replace the pump if
necessary.
20 No connection between Control
panel and the heater
Check wiring, connectors.
27 Air pump motor fault. Motor
won’t rotate
Check air pump motor
wiring, connector.
28 Air pump motor fault. Motor
won’t switch off, go on rotation
Check air pump motor
wiring, replace motor if
necessary.
7.3 Control Panel installation and connection
Control Panel is installed in cabin or passengers compartment on the dashboard
or any other comfortable for the driver place.
The control Panel is fixed with double-faced adhesive tape, which is stuck to the
back side of the Control Panel. You can take out wires of the unit from its back or side
cover. It is necessary to degrease the surface used for Control panel installation. Take off
protective film from the tape and install the Control Panel on the prepared surface.
The connection of the Control panel to the heater is performed according wiring
diagram(see fig. 4.1)
7.4 Complex checkup of the Control Panel after installation
After installation and connection of the Control panel to the heater the checkup is
performed in following way:
-set up the necessary operation mode on the Control panel;
-check activation and deactivation of the heater;
-check deactivation of the heater while artificial failure (take off the connector
from the fuel pump during operation mode of the heater), while this the malfunction
code appears on the indicator.
7.5 Possible malfunctions
If after pressing any knob of the Control Panel the indicator is not lightning, there
should be checked:
- fuses-25A;
- connectors and wires.
The Control Panel is not subjected to repair, it should be replaced for a new one.