8.1 Heater Installation
Installed the heater indoors while bearing in mind the permissible operating
positions shown in Figure 5. The figure shows the two maximum assembly positions of
the heater. Positioned the heater’s inlet vent in such a way to prevent absorption of
vehicle/heater exhaust gas in normal operating conditions. The gap between the
walls/partitions and the edge of the inlet vent shall be at least 50 mm (see Figure 8.1).
When assembling or operating the heater, ensure that no foreign objects enter the
inlet/outlet vents. Prior to assembly, ensure availability of spare heating plug and bear
in mind dismantlement requirements, as this will permit easier maintenance in future.
See Figure 8.2 for how to position mounting holes to install the heater into the motor
vehicle casing. Overall and mounting Dimensions are on the fig.8.3
ATTENTION !! To ensure reliable performance, follow the above
recommendations carefully. Install the heater horizontally with the heating plug
in the up position as shown in Figure 8.1.
Figure 8.1 – Mounting Options