Battery Condition Indication
Battery connected BEFORE full Charge: Vb<11V YELLOW
Vb>11V GREEN
If Stop/Restart Button is Pressed during charging mode STOPS CHARGING AND ALLOWS RESET OF ALL SELECTIONS
Battery Sulfation check (AFTER FULL CHARGE): Vb<11V YELLOW
Vb>11V GREEN
Battery Sulfation check (AFTER FULL CHARGE): Vb<12.5V* YELLOW
Vb>12.5V* GREEN
*12.75V for Gel battery. *12.75-V for AGM battery setting. 12.5-V for Flooded battery
LED INDICATOR FUNCTIONS -- Tables 3 (top) and 4 A&B (bottom)
LED Status - (Power / Error and Charge LEDs) POWER / ERROR CHARGE - FLOAT
GREEN RED GREEN
A.C. power disconnected, battery connected correctly OFF OFF
A.C. power connected, battery connected GREEN OFF
A.C. power connected, battery connected (press Stop/Restart button) GREEN ON
At Soft mode, Bulk charge mode, Absorption mode GREEN ON
In Sulphate check mode Float charge mode GREEN FLASH
A.C. power connected Reversed Battery Polarity RED ON OFF
A.C. power connected, charger output Clip shorted RED ON OFF
A.C. power connected, battery voltage is less than 3V RED ON OFF
Timed-out when in SoftStart or Bulk mode RED FLASH OFF
Timed-out when in Absorption mode & Forced to Float mode RED FLASH FLASH
Battery Fault / Battery Weak RED FLASH OFF