Instruction manual

Rev. P-071510 P/N VDC12248-MNL
BatteryMINDer
®
Model 12248
Page 31
DETAILED SPECIFICATIONS - VDC Model No. 12248 (con’t.)
Absorption mode transitions to Float mode conditions in AGM setting:
Mode: 1) Charging current
2) 5 Hours Time-out: after 5 Hours unit switches to Float Charge Mode
Absorption mode Thermal Runaway Protection: Stops Charging when the second current sample is
larger the first current sample (Positive dI/dt)
Switch to Float mode in Bulk charge or Absorption mode when Battery type Button is Pressed For
3 Seconds or longer. GREEN Charge - Float LED will blink
Float Charge output Voltage control 13.4@24°C (75°F) ±0.25 Vdc
Float Charge current control (2A Rate) 1 Adc ±0.25
(4A Rate) 2 Adc ±0.25
(8A Rate) 4 Adc±0.25
Float charge transitions to PWM Float Charge Mode after 1 Hour
Float Pulse Charge voltage control 13.4@24°C ±0.25 Vdc
Float Pulse Charge current control: (2A Rate) 1 Adc ±0.25
(4A Rate) 2 Adc ±0.25
(8A Rate) 4 Adc ±0.25