Sensor Module Failure
6.27
The Sensor Module Failure code results when the
module fails an internal diagnostic test.
Reset the Control
Module by pressing the
“Reset” button on the
front of the unit
Does the module continue to
display the “Sensor Module
Failure” code?
No
Yes
The module has
returned to
Normal Operation
Replace the
Sensor Module
Reset the sensor module by turning
off the pilot circuit power. Note:
Before turning the module on, wait
approximately 5 seconds to allow for
a proper reset.
Yes
Yes
No
The module has
returned to
Normal Operation
Does the module continue to
display the “Sensor Module
Failure” code?
Note: The compressor will continue to run
without a functioning sensor module, however,
there will not be enhanced motor protection