200 D Dunstabzugshaube Afzuigkap Hotte aspirante Cooker Hood Montage- und Gebrauchsanweisung Installatie- en gebruksaanwijzing Manuel de montage et d’utilisation Operating and Installation Instructions
Contents Safety warnings for user for kitchen unit installer 57 Introduction Extractor version Filter version 59 Hood operation 60 Maintenance and care Metal grease filter Carbon filter Changing the light bulb Cleaning Special accessories Technical assistance service Guarantee conditions Service 61 Technic Details 67 Installation Electrical connection Wall unit mounting Wall mounting 68 56
Safety warnings for user ● Always cover lighted elements, to prevent excess heat from damaging the appliance. In the case of oil, gas and coal fired cookers it is essential to avoid open flames. ● Also, when frying, keep the deep frying pan on the cooker top/ cooker under careful control. ● The hot oil in the frying pan might ignite due to overheating. ● The risk of self-ignition increases when the oil being used is dirty. ● It is extremely important to note that overheating can cause a fire.
● The national decree on fuel-burning systems specifies a maximum depression of 0.04 bar in such rooms. ● The air outlet must not be connected to chimney flues or combustion gas ducts. The air outlet must under no circumstances be connected to ventilation ducts for rooms in which fuel-burning appliances are installed. ● It is advisable to apply for authorization from the relevant controlling authority when connecting the outlet to an unused chimney flue or combustion gas duct.
Introduction Extractor version l The hood is supplied as an extractor unit and can also be used with a filtering function by fitting one activated carbon filter (special accessory). l You will need original AEG activated carbon filter for this function (see Special Accessories). l The unit features two outlet holes, one of which A is located on the top of the unit while the other B is located on the rear.
Hood Operation ● The hood is fitted with a variable speed motor. The most effective use of the hood is obtained by switching it on a few minutes before you start cooking and leaving it on a for approximately 15 minutes after you have finished, thus ensuring all cooking odours are eliminated.
Maintenance and care ● The hood must always be disconnected from the mains power supply before beginning any maintenance work. Metal grease filter ● The purpose of the grease filters is to aspirate grease particles which form during cooking and it must always be used, either in the external evacuation or internal recycling function. Attention: the metal grease filters must be removed and washed, either by hand or in the dishwasher, every four weeks.
Carbon filter ● The activated carbon filter should only be used if you want to use the hood in its filtering function. ● To do this you will need an original AEG activated carbon filter (see special accessories). l Cleaning/replacing the carbon filter Unlike other carbon filters, the LONGLIFE carbon filter can be cleaned and reactivated. At normal use the filter should be cleaned every second month. The best way to clean the filter is in the dishwasher.
Warning ● Failure to observe the instructions on cleaning the unit and changing the filters will cause a fire hazard. You are therefore strongly recommended to follow these instructions. ● The manufacturer declines all responsibility for any damage to the motor or any fire damage linked to inappropriate maintenance or failure to observe the above safety recommendations. Changing the light bulb l l l l ● Disconnect the unit from the mains power supply. Remove the grease filters.
Cleaning ● Warning: always disconnect the hood from the mains power supply before cleaning it. Never insert pointed objects in the motor’s protective grid. ● Wash the outside surfaces using a delicate detergent solution. Never use caustic detergents or abrasive brushes or powders. ● Only ever clean the switch panel and filter grille using a damp cloth and delicate detergents. ● It is extremely important to clean the unit and change the filters at the recommended intervals.
Guarantee conditions Guarantee Conditions AEG offer the following guarantee to the first purchaser of this appliance. 1. The guarantee is valid for 12 months commencing when the appliance is handed over to the first retail purchaser, which must be verified by purchase invoice or similar documentation.The guarantee does not cover commercial use. 2. The guarantee covers all parts or components which fail due to faulty workmanship or faulty materials.
Before you move please contact your nearest Customer Care Centre, listed below, to give them details of your new home.They will then ensure that the local Service Organisation is aware of your move and able to look after you and your appliances.
Technic Details Dimensions: Height x Width x Depht (in cm) Maximum absorbed power: Motor absorption: Lighting: Length of the cable: 16,3 x 59,9 x 53,5 200 W 120 W 2 x 40 W 115 cm 67
Electrical connection Safety warnings for the electrician Before connecting the appliance to the power supply, check that the voltage indicated on the rating plate corresponds to the mains power supply available. Appliances fitted with a plug can be connected to any standard power socket within easy access. Should it be necessary to provide a fixed connection, the hood must only be installed by an electrician authorised by the local electricity board.
Wall unit mounting - Fig. 6 l Make the holes on the bottom of the cupboard (2), using the drilling template (1). Provide an hole also for exhausting pipe (4) ONLY if is decided to use the hood in Exhausting version (3). l From inside the cupboard, insert the 4 supplied screws (5) and tighten them in the appropriate holes on the appliance. Fig.
Wall mounting - Fig. 7 l Sign a centerline onto the wall (1). Fit the template onto the wall (2). ● Fix the drilling template to the wall. ● Make 3 Ø 8mm holes in the wall (3), 2 at upper points, 1 as desired at lower points. ● Insert the three Ø 8mm expansion plugs into the wall (4). ● Insert 2 5x45 screws (5) but do not tighten them completely, hang the hood (6). ● Adjust the unit so that it is positioned at a right angle to the wall by turning the two screws on lower side (7).
71
AEG Hausgeräte GmbH Postfach 1036 D-90327 Nürnberg http://www.aeg.hausgeraete.de © Copyright by AEG LI1M8E Ed.