User Guide

30
F
F
Fig. 6
FO 0392
Injectors replacement
Remove the pan supports.
Remove the burner's caps and crowns.
With a socket spanner 7 unscrew and remove
the injectors (Fig. 6), and replace them with the
ones required for the type of gas in use (see
Technical data).
Reassemble the parts, following the same
procedure backwards.
Replace the rating label (placed near the gas
supply pipe) with the relevant one for the new
type of gas supply. You can find this label in the
package of the injectors supplied with the
appliance.
Should the feeding gas pressure be different or variable
compared with the required pressure, an appropriate pressure adjuster must be fitted on the gas
supply pipe, in compliance with the rules in force.
Adjustment of minimum level
To adjust the minimum level of the burners,
proceed as follows:
Light the burner.
Turn the knob on the minimum position.
Remove the knob.
With a thin screwdriver, adjust the by-
pass screw (see Fig. 7). If changing
from natural gas to LPG,completely
tighten clockwise the screw, until a
small regular flame is obtained. If
changing from LPG to natural gas
unscrew about 1/4 turn the by-pass screw, until a small regular flame is obtained.
Finally check the flame does not go out when quickly turning the knob from the maximum position
to the minimum position.
This procedure can easily be carried out, anyhow the hob has been positioned or built in
the working top.
Adaptation to different types of gas
Fig. 7
By-pass