User Guide

31
F
FO 0257
Abb. 8
The appliance is designed to be connected to 230 V monophase electricity supply.
The connection must be carried out in compliance with the laws and regulations in force.
Before the appliance is connected:
1) check that the main fuse and the domestic installation can support the load (see the rating
label);
2) check that the power supply is properly earthed in compliance with the current rules;
3) check the socket or the double pole switch used for the electrical connection can be easily
reached with the appliance built in the forniture unit.
The appliance is supplied with a connection cable. This has to be provided with a proper
plug, able to support the load marked on the identification plate. The plug has to be fitted in
a proper socket.
If connecting the appliance directly to the electric system, it is necessary that you install a
double pole switch between the appliance and the electricity supply, with a minimum gap of
3 mm. between the switch contacts and of a type suitable for the required load in compliance
with the current rules.
The connection cable has to be placed in order that, in each part, it cannot reach a tempe-
rature 50 °C higher than the room temperature.
The brown coloured phase cable (fitted in the terminal block contact marked with "L") must
always be connected to the network phase.
Replacement of the voltage cable
Only cable types H05RR-F, H05V2V2-F T90 or
H05 BB-F must be used. The cable section must
be suitable to the voltage and the working tempe-
rature.
The yellow/green earth wire must be
approximately 2 cm. longer than the phase wires.
To open the terminal block and reach the terminals,
proceed as follows:
l insert the point of a screwdriver into the visible
protrunding part of the terminal block;
l exert a light pressure and lift (Fig. 8).
Electrical Connection