Installation Instructions
1 Attention: The new appliance may only be installed and connected by a registered expert.
Please comply with this. If you do not, any damage resulting is not covered by the warranty.
1 Safety information for the installer
If supply cord damaged, it must be replaced by the manufacturer or approved service
agent.
The electrical installation is to be set up so that the appliance can be isolated from the
mains with a minimum 3mm all-pole contact separation.
Suitable separation devices include e.g. cut-outs, fuses (screw fuses are to be taken
out of the holder), RCD’s and contactors.
Anti-shock protection must be provided by the installation.
The built-in unit must meet the stability requirements of DIN 68930.
Means for disconnection must be incorporated in the fixed wiring in accordance with
the local wiring rules.
The use of thermal insulation bars is not permitted in cookers with Pyroluxe, if the recess
has a back wall and a solid shelf.
However with a shelf shortened by at least 20 mm and ventilation in the plinth of the
same diameter, it becomes possible to build-in.