User manual

Replacement of the connection cable
To replace the connection cable use only H05V2V2-F T90 or equivalent type. Make sure that
the cable section is applicable to the voltage and the working temperature. The yellow/
green earth wire must be approximately 2 cm longer than the brown (or black) phase wire.
Building In
min. 55 mm
min. 650 mm
750 mm
min. 100 mm
40 mm
490 mm
+2
0
+2
0
A
A - supplied brackets
Possibilities for insertion
Kitchen unit with door
The panel installed below the hob must be easy to remove and let an easy access in case a
technical assistance intervention is necessary.
min 20 mm
(max 150 mm)
40 mm
60 mm
a
b
a) Removable panel
b) Space for connections
Kitchen unit with oven
The hob recess dimensions must obey the indication and the kitchen unit must be equipped
with vents to let a continuous supply of air. The electrical connection of the hob and the
oven must be installed separately for safety reasons and to let easy remove oven from the
unit.
Installation
11