User manual

37Installation
Position Niche size Chimney Gap between
W D H (mm) cupboard & ceiling
The microwave can be fitted in position A, B or C:
INSTALLATION
Installing the appliance
1. Remove all packaging and check carefully for any signs
of damage.
2. If the microwave is fitted in position C, ensure that the
minimum air gaps are maintained as shown in the
diagram.
3. Secure four cupboard retention blocks in position using
the setting template (TMAPTA004URR0).
4. Fit the appliance into the kitchen cupboard, lift over the
bottom/front blocks then push slowly, and without
force, until the front frame of the oven seals against
the front opening of the cupboard.
5. Ensure the appliance is stable and not leaning.
6. Fix the oven in position with the screws provided.
The fixing points are located within the louvre areas at
the top and bottom of the oven (see diagram, item 1,
on page 7).
7. Fit the frame fastner caps to the four fixing positions (2
spare caps are provided).
8. It is important to ensure that the installation of this
product conforms to the instructions in this operation
manual and the conventional oven or hob
manufacturer’s installation instructions.
A 560 x 550 x 450 20 50
B 560 x 500 x 450 20 50
C 560 x 550 x 460 20 Not applicable
Measurements in (mm)
65 mm
5 mm
460 mm
20 mm
min. 20 mm
450 mm
min. 20 mm
450 mm
D
Position A
Position C
P
osition B
Conventional
oven
Chimney
Cable clip
Chimney
C
able
clip
Conventional
oven
Position A
Position B
Position C