INSTALLATION AND ASSEMBLY
These hobs can be installed in a kitchen unit with an
opening for insertion whose dimensions are shown in
Fig. 12 and 13.
The edge of the cut out must have a minimum distance
from the rear wall of 55 mm.
If there are side walls, or sides of the furniture unit near
the hob, the cut out edges must have a minimum
distance of 100 mm.
Carry out the building in of the hob as follows:
put the relevant sealings, supplied with the hob, on
the edges of the cut out, taking care that the sealings
meet without overlapping;
place the hob in the cut out, taking care of its
centring;
fix the hob with the relevant screws (Fig. 14). The
traction of the screws is able to trace the sealing, any
excess of which can then be easily removed.
The edge of the hob forms a double labyrinth seal
which provides a total guarantee against infiltration of
liquids.
Fig. 12
Fig. 14
FO 2138
FO 0199
a
a) sealing gasket
Fig. 13
FO 2101
830
480
55 min.
30
560
480
55 min.
30