User Guide

24
F
D
PR18
F
F
F
E
E
H
G
Rehingeing the door
The side at which the door opens can be changed from the right side (fac-
tory adjustment) to the left side, if the installation site requires.
Warning! When changing the side at which the door opens, the appliance
may not be connected to the mains. Remove plug from the mains befo-
rehand.
Procced as follow:
1. Remove the clip-in ventilation grille
(D).
2. Remove the bottom hinge (E) by
unscrewing the fixing screws.
3. Slide the bottom door off the centre
hinge (H).
4. Remove the centre hinge and slide
the top door off pin (G); unscrew pin
(G) and refit it on the opposite side.
5. Remove the two plugs, to reveal the
holes for the hinge pivots, and
remount them on the other side.
6. Refit the top door and the centre
hinge (H) on the opposite side.
7. Refit the bottom door.
8. Using a 10 mm spanner, unscrew
the hinge pin (E) and reassemble it
on the opposite side of the hinge;
9. Refit bottom hinge (E) on the oppo-
site side, using the screws previously
removed.
10. Remove blanking cover (F) from ven-
tilation grille (D) by pushing it in the
direction of the arrow and refit it on
the opposite side.
11. Refit ventilation grille (D), clipping it
into place.
33
Changing the light bulb
Warning! There is a risk of electric shocks! Before changing the light bulb,
switch off the appliance and unplug it, or pull the fuse or the circuit breaker.
Light bulb data: 220-240 V, max. 15 W
1. To switch off the appliance, turn the temperature regulator to position "0".
2. Unplug the mains plug.
3. To change the light bulb, undo the
screw.
4. Press the light bulb cover as shown
and slide it backwards.
5. Change the defective light bulb.
6. Refit the light bulb cover and the
screw.
7. Put the refrigerator back into opera-
tion.
D411
Regulations, Standards, Guidelines
This appliance was designed for household use and was manufactured in
accordance with the appropriate standards. The necessary measures in
accordance with appliance safety legislation regulations (GSG), accident
prevention regulations for refrigeration appliances (VBG 20) and the regu-
lations of the German Society of Electrical Engineers (VDE) were observed in
the manufacture of this appliance.
The refrigerant circuit has been checked for leaks.
This appliance is in accordance with the following EU guidelines:
73/23/EWG dated 19 February 1973 - low voltage guidelines.
89/336/EWG dated 3 May 1989
(including guideline change notice 92/31/EWG) - EMV guideline