5.1.2.1 Instruction specific output
After entering a valid command without a parameter value, the system answers by sending the param-
eter value and <CR>. Example:
Command: GT <CR>
Output: Transponder number or No Read <CR>
Command: RST <CR>
Output: If EC is active the boot message, else <CR>
5.1.2.2 Output after changing a parameter
After entering a valid command together with a parameter value, the system answers by sending the
parameter value and <CR>. Example:
Command: MD <SP> 2 <CR>
Output: 2 <CR>
After entering an invalid parameter value, the system answers with the corresponding error code. Error
message:
Command: MD <SP> 4 <CR>
Output: <NAK> #02 <CR>
5.1.2.3 Output at parameter query
Parameter settings can be queried by sending the command without adding a parameter value. Exam-
ple: