5.3.4 NID – Failure Protection
NID specifies the number of identical transponder numbers, which have to appear for the result “suc-
cessful reading“ within a reading cycle. In the setting NID = 1, two successive readings have to show
the same transponder number.
Input format: NID <SP> parameter <CR>
Parameter:
PARAMETER FUNCTION
0 One out of one
1 Two out of two
Output (example): 1 <CR>
Sequence of readings Lenght of the read-
ing cycle
Result of the read-
ing cycle
NoRead 1 reading NoRead
0000125ED1, 0000125ED1 2 readings 0000125ED1
0000125ED1, 0000126ED1 2 readings NoRead
5.3.5 TOR – Maximum reading time
Timeout for the reader. TOR is used in operation mode 2 as maximum gating time for a reading pro-
cess. The length of the maximum gating time results from the equation gating_time = TOR * TB.
Default value = Tor 50
The time constant TB (Time Base) has always the default value 100ms.
Input format: TOR <SP> parameter <CR>