Parameter:
PARAMETER FUNCTION
0 limits the reading process duration of exactly one reading cycle
1 limits the reading process duration to maximum 1 times TB
2 limits the reading process duration to maximum 2 times TB
...
255 limits the reading process duration to maximum 255 times TB
Output (example): 2 <CR>
5.4 Instructions for the memory settings
5.4.1 VER – Reader firmware
With the command VER you get the actual reader firmware.
Input format: VER <CR>
Output (example): V_2.08 <CR>
Note: If the EC = 1 you will get the same message after each system start.
5.4.2 VS – Show parameter
The command VS lists all current parameter settings.
Input format: VS <CR>
Output (example): EC <SP> 0 <CR>
BD <SP> 2 <CR>
MD <SP> 2 <CR>