Instructions

www.aeg-automotive.com
30
Jump Start mode
If the connected battery has less than 14.7 V, rst a
charging process will automatically be used before
the device switches to Jump Start mode.
When pressing and holding the button
(27) for
3 seconds the charger will directly switch to Jump
Start mode without charging.
CHARGING
CURRENT
12 V/5 A and 24 V/20 A: Intended Use
To charge low and medium capacity batteries
(12 V/24 V) (e.g. lorries or tractors).
12 V/60 A and 24 V/20 A: Intended Use
For charging high capacity batteries (e.g. marine
or large deep-cycle batteries) or to quick-charge
medium or higher capacity batteries.
Jump Start: Intended Use
Helps start vehicles and equipment with a weak
battery.
12 V: slow charging
Model
Charging voltage
(V)
Charging current
(A)
LT60 12 V
5 A / 20 A / 60 A
RMS
24 V: slow charging
Model
Charging voltage
(V)
Charging current
(A)
LT60 24 V
2 A / 10 A / 20 A
RMS
Jump start function
Model
Charging voltage
(V)
Charging current
(A)
LT60 12 V 540 A
SAFETY
FUNCTIONS
The charger features the following safety features
to prevent damage to the charger and the battery
or the vehicle:
Short circuit (defective battery),
incorrect connection (connected with reversed
polarity),
overheating
excess current
overcharging