BURNER Ø BYPASS 1/100 mm
Grill 59
14.5 Gas burners for NATURAL GAS G20 2.0 kPa
BURNER NORMAL POWER
kW
REDUCED POWER kW INJECTOR MARK
1/100 mm
Rapid 3.0 0.75 119
Semi-rapid 2.0 0.45 96
Auxiliary 1.0 0.35 70
Oven 2.25 1.0 108
Grill 2.0 1.5 108
14.6 Gas burners for LPG G30 2.8-3.0 kPa
BURNER NORMAL POWER
kW
REDUCED POWER kW INJECTOR MARK
1/100 mm
Rapid 3.0 0.72 88
Semi-rapid 2.0 0.43 71
Auxiliary 1.0 0.35 50
Oven 2.25 1.0 71
Grill 2.0 1.5 71
14.7 Gas connection
Use a fixed connections or use a flexible
stainless steel pipes in compliance with
the regulation in force. If you use flexible
metallic pipes, make sure they do not
come in touch with mobile parts and
they are not squeezed.
14.8 Flexible nonmetal pipes
connection
If you have an easy access to the
connection, you can use a flexible pipe.
The flexible pipe must be tightly
attached by clamps.
In installation always use the pipe holder
and the gasket. The flexible pipe can be
applied when:
it can not get hotter than room
temperature, higher than 30 °C,
it is not longer than 1500 mm,
it has no narrowing anywhere,
it is not twisted or tighten,
it does not get in touch with sharp
edges or corners,
it's conditions can be easily checked.
When checking the flexible pipe make
sure:
ENGLISH