User manual
Table Of Contents
- CONTENTS
- 1. SAFETY INFORMATION
- 2. SAFETY INSTRUCTIONS
- 3. PRODUCT DESCRIPTION
- 4. BEFORE FIRST USE
- 5. HOB - DAILY USE
- 6. HOB - HINTS AND TIPS
- 7. HOB - CARE AND CLEANING
- 8. OVEN - DAILY USE
- 9. OVEN - CLOCK FUNCTIONS
- 10. OVEN - USING THE ACCESSORIES
- 11. OVEN - HINTS AND TIPS
- 12. OVEN - CARE AND CLEANING
- 13. TROUBLESHOOTING
- 14. INSTALLATION
- 14.1 Location of the appliance
- 14.2 Technical data
- 14.3 Other technical data
- 14.4 Bypass diameters
- 14.5 Gas burners for NATURAL GAS G20 2.0 kPa
- 14.6 Gas burners for LPG G30 2.8-3.0 kPa
- 14.7 Gas connection
- 14.8 Flexible nonmetal pipes connection
- 14.9 Adjustment to different types of gas
- 14.10 Hob injectors replacement
- 14.11 Adjusting the minimum gas level on the hob burner
- 14.12 Oven injector replacement
- 14.13 Adjusting the minimum gas level on the oven burner
- 14.14 Gas grill injector replacement
- 14.15 Levelling
- 14.16 Backguard
- 14.17 Electrical installation
![](/manual/aeg/10369gn-mn/user-manual-english/images/img-24.png)
Dimension mm
B 650
C 150
D 20
14.2 Technical data
Voltage 220 - 240 V
Frequency 50 / 60 Hz
Appliance class 1
Dimension mm
Height 885 - 915
Width 900
Depth 600
14.3 Other technical data
LPG: G30 2.8-3.0 kPa
Natural Gas: G20 2.0 kPa
14.4 Bypass diameters
BURNER Ø BYPASS 1/100 mm
Auxiliary 29 / 30
Semi-rapid 32
Rapid 42
Triple Crown 67
Oven 54
Grill 59
14.5 Gas burners for NATURAL GAS G20 2.0 kPa
BURNER NORMAL POWER
kW
REDUCED POWER kW INJECTOR MARK
1/100 mm
Triple Crown 4.0 1.8 146
Rapid 3.0 0.72 119
Semi-rapid 2.0 0.43 96
Auxiliary 1.0 0.35 70
Oven 3.6 1.5 126
Grill 2.5 1.6 111
ENGLISH 25