User manual

37
Select the hood operating mode
Extractor operationExtractor operation
Extractor operationExtractor operation
Extractor operation
Fix the 150 mm diameter ABS pipe to the hood outlet and
ensure that the other end discharges into the open air.
The hood is supplied with a reducer for 120 mm diameter
pipes. This reducer must be mounted on the hood outlet.
Filter operationFilter operation
Filter operationFilter operation
Filter operation
If the connector ring has not yet been installed, it must be
fitted at this point (
QQ
QQ
Q in
Fig. 7Fig. 7
Fig. 7Fig. 7
Fig. 7, bayonet
connector). Turn it in a
clockwise direction and
fix it to the air pipe L
using a screw. Insert the
air pipe into the
telescopic chimney
support and fix it with
four screws (Ø 2,9 x 9,5
mm).
Fig. 7Fig. 7
Fig. 7Fig. 7
Fig. 7.
Fix the 150 mm diameter
ABS pipe to the hood
outlet, and connect it to
the air pipe connector
ring.
For both versions:
The hood can now be connected to the power supply.
If a gas non-return valve has been installed or is required,
ensure that it opens and closes properly.
Fix the top part the telescopic outlet pipe to the relative
support, using the two 3 mm dia x 9 mm screws
R.R.
R.R.
R.
Fig. 6.Fig. 6.
Fig. 6.Fig. 6.
Fig. 6.
Slide the bottom part of the telescopic outlet pipe
downward until it rests in its housing on the top of the
hood.
Replace the grease filters.
Q
L
Fig. 7Fig. 7
Fig. 7Fig. 7
Fig. 7