User manual

32
InstallationInstallation
InstallationInstallation
Installation
Safety warnings for kitchen unit installerSafety warnings for kitchen unit installer
Safety warnings for kitchen unit installerSafety warnings for kitchen unit installer
Safety warnings for kitchen unit installer
When used as an extractor unit, the hood must be fitted
with a 150mm diameter hose.
If the fumes must be forced out through the wall, you
must obtain a MKZ150 sizable wall exhaust pipe (with
external exhaust and air intake), E-Nr.- 942 118 609 (Ø
150 mm) which is one of our optional parts.
When installing the hood, make sure you respect theWhen installing the hood, make sure you respect the
When installing the hood, make sure you respect theWhen installing the hood, make sure you respect the
When installing the hood, make sure you respect the
following minimum distance from the top edge of thefollowing minimum distance from the top edge of the
following minimum distance from the top edge of thefollowing minimum distance from the top edge of the
following minimum distance from the top edge of the
cooking hob/ring surfaces:cooking hob/ring surfaces:
cooking hob/ring surfaces:cooking hob/ring surfaces:
cooking hob/ring surfaces:
electric cookerselectric cookers
electric cookerselectric cookers
electric cookers
600 mm600 mm
600 mm600 mm
600 mm
gas cookersgas cookers
gas cookersgas cookers
gas cookers
650 mm650 mm
650 mm650 mm
650 mm
coal and oil cookerscoal and oil cookers
coal and oil cookerscoal and oil cookers
coal and oil cookers
700 mm min.700 mm min.
700 mm min.700 mm min.
700 mm min.
The air outlet must not be connected to chimney flues or
combustion gas ducts. The air outlet must under no cir-
cumstances be connected to ventilation ducts for rooms
in which fuel-burning appliances are installed.
It is advisable to apply for authorization from the
relevant controlling authority when connecting the outlet
to an unused chimney flue or combustion gas duct.
The air outlet installation must comply with the
regulations laid down by the relevant authorities.
When the unit is used in its extractor version, a
sufficiently large ventilation hole must be provided, with
dimensions that are approximately the same as the outlet
hole.
National and regional building regulations impose a
number of restrictions on using hoods and fuel-burning
appliances connected to a chimney, such as coal or oil
room-heaters and gas fires, in the same room.
The national decree on fuel-burning systems specifies a
maximum depression of 0.04 bar in such rooms.