User manual

Gas burners
Burner Normal
power
Reduced
power
Type of
gas
Pres-
sure
Injector
diame-
ter
Usage
kW kW mbar mm g/h
Auxiliary
burner
1,00 0,40 Natural
Gas G20
13 0,82 -
1,00 0,35 Natural
Gas G20
20 0,70 -
1,00 0,35 Butane
G30
28 -
30
0,50 72,71
0,85 0,31 Propane
G31
28 -
30
0,50 60,70
Semi-rap-
id burner
2,00 0,50 Natural
Gas G20
13 1,11 -
2,00 0,43 Natural
Gas G20
20 0,96
2,00 0,43 Butane
G30
28 -
30
0,71 145,43
1,70 0,38 Propane
G31
28 -
30
0,71 121,40
Triple
crown
burner
4,00 1,80 Natural
Gas G20
13 1,74 -
4,00 1,80 Natural
Gas G20
20 1,46
4,00 1,80 Butane
G30
28 -
30
1,01 290,85
3,50 1,60 Propane
G31
28 -
30
1,01 249,95
Oven 2,70 0,90 Natural
Gas G20
13 1,30 -
2,70 0,90 Natural
Gas G20
20 1,20 -
2,70 0,90 Butane
G30
28 -
30
0,80 196,33
2,35 0,78 Propane
G31
28 -
30
0,80 167,82
13.3 Gas Connection
Choose fixed connections or use a flexi-
ble pipe in stainless steel in compliance
with the regulation in force. If you use
flexible metallic pipes, be careful they
do not come in touch with mobile parts
or they are not squeezed.
13.4 Flexible nonmetal pipes
connection
If it is possible to easily control the con-
nection in its full area, you can use a flex-
ible pipe. The flexible pipe must be
tightly attached by clamps.
ENGLISH 23