User manual

16
Fixing
* Prepare the cut out according to
the "cut out measurements”.
* Drop the outer housing into the
bench top and fix down with
countersink screws through the
sides or the ends of the outer
housing into the bench material.
WARNING: DO NOT install the
hotplate without the outer housing.
Hotplate will not operate correctly
without outer housing fitted.
* Feed the electrical plug and cable
through the hole in the outer housing
and lower the hotplate into position.
* Fix the hotplate to the bench by
fitting the four self drilling screws
supplied through the base of the
outer housing.
Gas installation
The appliance is factory set for Natural
Gas. Fit the gas regulator supplied with
the hob to the gas inlet. The location of
the gas inlet is approximately 240mm
form the right hand side of the hob and
40mm from the back of the hob. The
connection of the Gas Regulator is ½”
Gas female thread and the pressure at
the test point should be adjusted
to1.00kPa with the large and simmer
burners operating at maximum.
For Universal LPG connection, the
hob
needs to be first converted using the
conversion kit and instructions
supplied with the hob.
Do not use any other components.
Do not use the Gas regulator supplied
with the hob, a gas regulator suitable
for a supply pressure of 2.75kPa
should be part of the gas tank supply
and should be adjusted with the large
and simmer burners operating at
maximum.
Electrical Connection
This appliance is supplied with an
1800mm long flexible supply lead
and 3 pin plug. The point of
connection is located at the rear and
on the underside of the appliance.
Connect the appliance to a readily
accessible switched general purpose
outlet which is adjacent to the
appliance.
THIS APPLIANCE MUST BE
CONNECTED TO AN EARTHED
GENERAL PURPOSE OUTLET.
Outer housing