INSTRUCTION BOOK 353 WK-m 1 ZA GB 949600806
Congratulations from AEG Dear Customer, Congratulations with your new Hob. It is important that you become familiar with the functions and features of the Hob. You should therefore read these operating instructions as they will help you get the most out of your new Hob. Pay extra attention to sections marked . These are warning texts to help you avoid accidents. Keep the operating instructions.
Table of contents Contents Page no For the user Your new appliance ...................................................................................... 2 Safety information ........................................................................................ 4 Description of the product ......................................................................... 5 Placement of grid ................................................................................. 5 Operating instructions ...............
Safety information These warnings are provided in the interests of your safety. Ensure you fully understand them before installing or using the appliance. Your safety is of paramount importance. If you are unsure about the meaning of these warnings contact the Customer Care Department for assistance. Child Safety Installing Maintenance and Cleaning This wok must be installed according to the instructions supplied. Any installation work must be undertaken by a qualified competent person.
Description of the product Burner Knob Placement of grid Guide knop for grid 5
Operatings instructions The operating knob has a ring showing the scale of markings. Off. Max. flame and ignition position Min.
Burner cover/inner burner ring/outer burner ring Together with the inner burner ring the outer burner ring forms a space where the final mixture of gas and air takes place in order to make the gas burn correctly. Cover Burner ring Please note: It is consequently very important that the inner burner ring/outer burner ring is placed correctly, together with the cover.
Outer burnerring Cover Inner burnering Air valve Burner body 8
Please note: If the wok is mounted in a table top with a cupboard underneath, the flame might be blown out if the door is slammed. The wok-unit has a special pan support which enables use of a wok pot with curved bottom. When using cooking utensils with a flat bottom the diameter of the utensils must not be less than 26 cm.
Ignitions 1. Depress and turn the control knob for the burner, the left to Max. flame 2. The ignition electrode will emit sparks, and when the mixture of gas and air is correct, the burner will be ignited. Is not possible to connect the unit to mains, a match may be used to ignite the burner 3. After starting the burner, press the control knob for approx. 10 seconds to activate the automatic thermo couple. 4.
Cleaning and maintenance of For reasons of hygiene and safety, the cooking burner must be kept clean. Grease stains and spilled food generate smoke when heated, and can even cause fire. The splashguard can be removed to make it easier to clean the surface. What to do: 1. Hold the splashguard as shown in the diagram. 2. Lift the splashguard straight up 3. Clean the top surface as described in “cleaning the steel surface”. Be aware of the two retaining pegs, which are sharp. 4.
Stainless steel surfaces Perform daily cleaning with a slightly damp cloth. For more severe soiling, use a liquid cream. Always clean the steel in the direction of the steel finish. To ensure that the steel retains its shine, it is recommended that you use a polishing agent for stainless steel on a regular basis. Always polish in the direction of the steel finish (crosswise). Never use steel wool, metal sponges or other abrasive cleaning agents.
Mounting Caution: In order to avoid a hazard this appliance must be installed according to these instructions for installation The hob unit can be mounted in any type of kitchen with a table surface whose thickness is between 28 mm and 40 mm. Headroom The distance to any shelves or tops of a cabinet under the hob is to be at least 47 Minimum distance mm. to wall: 150 mm Fixing Screw the fixing brackets out to such an extent that they can be turned in under the table top.
It is not necessary to attach the reinforcement beam to the work top surface, as it is held in place by a specially designed moulding, which is incorporated in the hob units flanges.
Installation of wok burner It is extremely important that both the inner and outer burner rings are fitted correctly into their “guide notch”, otherwise the burner will burn with an incorrect flame pattern and could be ruined within a very short period. You must be able to hear a click telling you that the rings have been correctly fitted. Air valve Fig. 1 How to proceed: 1. Fit the air valve in the burner body. See fig. 1 Inner burner ring Fig. 2 2.
Cover plate 3. Place the cover plate over. See fig. 3. Fig. 3 Fig. 4 4. Finally, fit the outer burner ring, taking care that the guide pin engages in the notch. See fig. 4.
Gas installation In accordance with local requirements for domestic gas cooking appliances. Gas installation must only be carried out by an authorised person. For gas types see technical data. Gas connection The gas intake is situated at the lower rear of the appliance. The intake has a ½" conical pipe thread (see fig 1) If the appliance is to be connected to a gas cylinder, conversion with the optional modification kit will be necessary. Pressure test The unit should be pressure-tested at Max. 150 mbar.
An opening with a minimum area of 60 cm2 must be present at the back of the cupboard (see fig.).
Technical data Type of gas Adjusted for: Natural, G-20 - 20mbar 230 V 1N + PE Category and pressures ZA: II2E3B/P 20-50 mbar N L1 Max. nominal load Q, HS: Wok burner = 5,0 kW x 1 Total= 5,0 kW The Dropinett must be connected via an external switch with a contact gap of min. 3 mm (the main switch Convertible to bottledgas - G30-50 mbar may be used) FSD The unit features fully-secured gas taps (thermo-fuse).
Service Question: Answer There is no spark when lighting the gas? Check whether the 230 V connection has been plugged in. The ground fault circuit relay way have switched off. The fuse has blown When the operating knob is released the gas ring goes out again? The operating knob has not been depressed long enough, or has not been depressed sufficiently. The gas ring burns very unevenly?? Check whether the cover has been replaced correctly, e.g. after cleaning.
24 325 88-1657 Rev.