User manual

17
Electrical connections
The appliance is designed to be connected to 230 V monophase electricity supply.
The connection must be carried out in compliance with the laws and regulations in force.
Before the appliance is connected:
1) check that the main fuse and the domestic installation can support the load (see the rating
label);
2) check that the power supply is properly earthed in compliance with the current rules;
3) check the socket or the double pole switch used for the electrical connection can be easily
reached with the appliance built in the forniture unit.
The appliance is supplied with a connection cable. This has to be provided with a proper plug, able
to support the load marked on the identification plate. The plug has to be fitted in a proper socket.
If connecting the appliance directly to the electric system, it is necessary that you install a double
pole switch between the appliance and the electricity supply, with a minimum gap of 3 mm.
between the switch contacts and of a type suitable for the required load in compliance with the
current rules.
The connection cable has to be placed in order that, in each part, it cannot reach a room
temperature higher than 90 °C.
The brown coloured phase cable (fitted in the terminal block contact marked with "L") must always
be connected to the network phase.
Replacement of the voltage cable
The replacement of the voltage cable requires the specific
equipment of a technician.
In this case, only cable type H05 V2V2-F must be used.
The cable section must be suitable to the voltage and the
working temperature.
The yellow/green earth wire must be approximately 2 cm.
longer than the phase wires.
To open the terminal block and reach the terminals, proceed
as follows:
insert the point of a screwdriver into the visible protruding
part of the terminal block;
exert a light pressure and lift. (Fig. 11)
FO 0257
Fig. 11
Earth (yellow/green)
Neutral