User manual

13.5 Gas burners
BURNER NORMAL POWER
kW
Natural Gas
INJECTOR MARK 1/100
mm
Btu/h
Auxiliary 1 70 3412
Semi-rapid 1.9 96 6483
Multi crown 3.4 136 11600
13.6 Gas Connection
Use a flexible pipe in compliance with
the regulation in force. Make sure they
do not come in touch with mobile parts
and are not squeezed.
WARNING!
Only a qualified and
competent person can do
the gas installation.
Before you connect te gas,
disconnect the appliance
from the electricity supply or
switch off the fuse in the fuse
box. Close the primary valve
of the gas supply.
Supply piping should not be
less than R3/8. Connection is
made to the Rc 1/2 (1/2
“ B.S.P.) female threaded.
The entry pipe is located just
below the hob level on the
rear left hand side of the
appliance.
The gas supply ramp is on
the rear side of the
appliance.
WARNING!
Only liquid sealants can be
used when the inlet gas pipe
is fitted i.e.: do not use the
P.T.F.E. sealant tape.
When the installation is
complete, carry out a gas
tightness test and make sure
that the seal of each pipe
fitting does not leak.
Use flexible tubing, which
comply with the BS.669
current edition.
A
B
C
C
D
E
WARNING!
The gas bayonet connector
must be in the marked area.
Dimension mm
A 250
B 680
C 50
D 250
E 580
13.7 Pressure test
The Rapid injector is used as a pressure
test point.
www.aeg.com
28