PROTECT Uninterruptible Power Supplies and Surge Protection for Data & IT applications Date 2011 PERFECT IN FORM AND FUNCTION
UPS The right UPS for every application. AEG Power Solutions provides customized solutions for protection against network disruptions and the loss of data and costly downtime periods suffered as a result. ”Plug & Safe“ options Our range of compact UPS systems includes UPS devices for private use, systems which can be incorporated into racks for the IT cabinet and “Plug & Safe” parallel switchable modular UPS systems for computer centers and industry.
UPS Milestones 2009 AEG Power Solutions becomes a listed company through its holding company 3W Power SA 2008 Renaming of Saft Power Systems Group to AEG Power Solutions 2005 Saft Power Systems Group becomes independent 1998 Saft acquires AEG SVS Power Supply Systems GmbH in Belecke 1995 First UPS in the world with 100% digital control system called Protect 3.
Surge protectors HOME Protect Basic. Protect Entertainment. Protect TwinPower. Protection for all standard applications Intelligent protection for entertainment equipment with Master-Slave-Function Security for various applications with protected USB chargers 6 (GE6) / 7 (GE7) 9 - 6 9 4+1 2 9 2 - cable fixture (Basic.
Surge protectors OFFICE Protect Travel. Protect Office. Protect TwinPower.
Compact UPS: Home/Office IT Page Power (kVA) Technology acc. to IEC 62040-3 Input/Output Parallel operation Autonomy time (min.) at full load Protect Home. (GE/FR/UK) * Protect A. 600 VA. Comprehensive protection for satellite, TV, phone, fax or modem. 500 to 1400 VA. Protects PCs, workstations and phone systems. 18 20 0.6 kVA 0.5 - 1.
Compact UPS: IT equipment Protect B. Protect B. PRO 750 to 3000 VA. Rack or tower for server and network components with sinusoidal output. 750 to 3000 VA. Efficient Rack/Tower-UPS with sinusoidal output for small servers and networks 22 24 0.75 - 3 kVA 0.
Compact UPS: medium-sized IT facilities Page Power (kVA) Technology acc. to IEC 62040-3 Input/Output Parallel operation Autonomy time (min.) at full load Protect C. * Protect C. Rack * 1 to 10 kVA. Tower UPS for sensitive networks, small computer centres, Intranet and Internet servers. 1 to 6 kVA. UPS for rack usage to protect sensitive networks, small computer centres, Intranet and Internet servers.
Compact UPS: medium-sized IT facilities Protect D. Protect 1. 1 to 10 kVA. Compact UPS for rack usage protects server, networks and IT equipment. 10 to 20 kVA. For medium-sized data centers, protection of cash till systems and facilities.
modular UPS: medium-sized datacenters Page Power (kVA) Technology acc. to IEC 62040-3 Input/Output Parallel operation Autonomy time (min.) at full load Protect 1.M Protect 3.M 2.0 4 to 24 kVA. Scaleable and modular high-performance UPS system for the IT sector. 20 to 120 kVA. Modular UPS with “hot swappable” design as scalable solution for medium-sized data centers.
3 phase UPS: large datacenters Protect 3.33 Protect 4.33 10 to 120 kVA. High-availability-UPS for hosting, file servers, workstations and data centers, also for their integration in complex networks 160 to 1000 kVA.
Surge protection When voltage rises ... Surge protection Surges can be caused, for example,by lightning striking near your premises. Lightning induces voltage surges in conductors and cables that can damage any connected equipment. Switching in households, with conventional power supplies of fluorescent lamps for example, can also cause surges in the wiring system of a building.
Surge protection 13 Protect Basic.GE: Effective surge protection for sensitive home electronics The surge protectors have five outlets for standard grounded power plugs, plus one or two wider-spaced outlets designed to accommodate larger power adapters. The surge protectors include filters to suppress high-frequency interference voltages. To prevent tangled cables, they are also fitted with a cable management bracket at one end. Two LEDs indicate whether the power is on and surge protection is active.
Surge protection Protect Office: Compact protection for PC and peripheral equipment Protect Office. is the compact power distribution for your desktop. The 3 power outlets and network ports provide complete computer protection. During the development phase, the compactness of design was paramount. The design also allows you to connect a microphone and speakers. As a result, the annoying cable clutter on and behind the desk can be avoided.
Surge protection 15 Protect Entertainment: Intelligent protection for entertainment equipment with Master-Slave-Function Protect your sensitive equipment and save standby costs. With its Master-SlaveFunction, the PROTECT Entertainment. is especially suited to modern home theatres and music systems. If the main unit (master) is turned off, then the electricity supply of the other peripheral units (slaves) will be automatically cut off.
UPS technology Optimal protection for every application Outage-blackouts ( > 10ms) VFD VI VFI Sags/brownouts Dynamic overvoltage Undervoltage (continuous) Overvoltage (continuous) Transients/Surges Frequency variations Voltage distortions (bursts) Voltage harmonics Lightning Uninterruptible power supply The VFD technology protects against the mains variations caused by network disruptions, brownouts and voltage peaks. Mains voltage variations occur more often than expected.
UPS technologies VFD acc. to IEC 62040-3 (offline) Advantages: Disadvantages: Mains Transfer unit r most compact solutions possible r transfer gap (some ms) Load r high efficiency, low running costs r load is fed by unfiltered voltage (no correction by the inverter) r low cost solutions VI Rectifier Battery r output voltage often not sinusoidal Inverter acc.
Protect Home. Reliability Protect Home: Uninterrupted Protection for PCs Protection against data loss through uninterrupted power protection with a size from 600 VA, the Protect Home. offers professional and economical protection against power outages, surges and sags. VFD Practical Protection Especially for multi-media applications, the Protect Home. offers data line protection for telephones, faxes and modems as well as surge protection for satellite TV.
Protect Home. and Multimedia. Classification VFD SY 322 acc. to IEC 62040-3 PROTECT Home. Type power Part number 600 VA/300 W 600 000 3933 UPS INPUT Input voltage Frequency Current consumption (max.) 230 Vac 50 Hz 3.0 A UPS OUTPUT Rated output voltage Rated output voltage in battery mode Frequency in battery mode Output current Transfer time at mains outage Voltage waveform Overload/Short Circuit Protection 230 Vac ± 10 % 50 Hz ± 1 Hz 2.
Protect A.
Protect A. ations and telephone systems. Classification VI SY 322 acc. to IEC 62040-3 Type rating Part number A. 500 A. 700 A. 1000 A.
Protect B.
Protect B. output for server and network components. Classification VI SS 211 acc. to IEC 62040-3 Type power Part number (BatteryPack) B. 750 B. 1000 B. 1500* B. 2000* B. 3000* 750 VA 500 W 600 000 3916 1000 VA 700 W 600 000 3917 1500 VA 1050 W 600 000 3918 600 000 4095 2000 VA 1340 W 600 000 3919 600 000 3921 3000 VA 2100 W 600 000 3920 600 000 4921 UPS INPUT Input voltage Input voltage range without battery mode Frequency (auto selection) Current consumption (max.
Protect B. PRO Reliability Protect B. PRO: Efficient protection with innovative High level flexibility, intelligent functions r Modern VI (line-interactive) protection technology with sine wave output voltage r Lower operating costs by higher efficiency (0.
Protect B. PRO features for server and networks. Classification VI SS 211 acc. to IEC 62040-3 B. 750 PRO B. 1000 PRO B. 1400 PRO B. 1800 PRO B. 2300 PRO B. 3000 PRO Type power 750 VA 675 W 1000 VA 900 W 1400 VA 1260 W Part number 600 000 8422 600 000 8424 600 000 8426 1800 VA 1620 W 600 000 8428 600 000 8429 (BP) 2300 VA 2070 W 3000 VA 2700 W 600 000 8431 600 000 8432 11 A 14.
Protect C.
Protect C. ectronic data processing in medium-sized companies. Classification VFI SS 211 acc. to IEC 62040-3 Classification VFI SS 111 acc. to IEC 62040-3 Type rating Part number (Tower) Part number (BatteryPack) Part number (Tower S-Version) C. 1000 C. 2000 C. 3000 1000 VA 700 W 2000 VA 1400 W 3000 VA 2100 W 600 000 5735 600 000 5739 600 000 4337 600 000 5736 600 000 5740 600 000 4338 600 000 5738 600 000 5740 600 000 4339 C. 6000 C.
Protect C. Rack Reliability Protect C. Rack: High performance UPS-system for IT Due to true online/double-conversion technology Protect C. is well suited for mission-critical applications such as sensitive networks, small computer centers, Intranet and Internet servers, telecom applications as well as for industrial applications. The Protect C. employs VFI topology to protect loads against all public grid disturbances.
Protect C. Rack 29 and electronic data processing in medium-sized companies. Classification VFI SS 211 acc. to IEC 62040-3 Classification VFI SS 111 acc. to IEC 62040-3 Type rating Part number (Rack) Part number (BatteryPack) Part number (Rack S-Version) C. 1000 R C. 2000 R C. 3000 R 1000 VA 700 W 600 000 3846 600 000 3851 600 000 4342 2000 VA 1400 W 600 000 3847 600 000 3852 600 000 4343 3000 VA 2100 W 600 000 3848 600 000 3852 600 000 4344 C.
Protect D. Reliability Protect D: Efficient high-performance UPS ideal Valuable features and easy control r VFI topology (online double-conversion): protects against all mains power disturbances r 20% higher available power by 0.
Protect D. for rack usage. Classification VFI SS 211 acc. to IEC 62040-3 Type rating Part number (UPS) Part number (BatteryPack) D. 1000 D. 1500 1000 VA 900 W 600 000 8434 600 000 8441 1500 VA 1350 W 600 000 8436 600 000 8442 D. 2000 D.
Protect 1. Reliability Protect 1: Online UPS systems for networks and r True online UPS including static bypass (double-conversion VFI-technology) r Power range 10,15, 20 kVA, space-saving design n + x technology (DSP controlled) to increase output power and/or for redundancy r State-of-the-art: High reliability and efficiency by digital signal processing (DSP), CAN bus system, and high frequency IGBT technology.
Protect 1. computer centers 10-20 kVA. Classification VFI SS 111 acc. to IEC 62040-3 Type power Part number (Tower) Protect 1.100 Protect 1.150 Protect 1.200 n + x technology scalable (parallel operation of up to 3 units) 10 kVA 15 kVA 20 kVA 7 kW 10.
16 34 Protect 1.M Reliability Protect 1.M: Modular high performance UPS system r High power reserves max.
Protect 1.M for IT environments. Classification VFI SS 111 acc. to IEC 62040-3 Protect 1.040 Type power UPS module 4 kVA 2.8 kW Part number 600 000 3928 Protect 1.M System unit with max. 6 x 4 kVA 24 kVA 16.8 kW n+x-scalable technology 600 000 3930 UPS INPUT Input voltage (auto. detection) Input voltage range without battery mode Frequency Current consumption (max.
Combination Architecture Next-generation UPS for a new world Combination Architecture Ever-tightening controls on carbon emissions. The need for ever greater computing capacity. And the challenge of controlling power costs. Always at the forefront of power innovation, AEG Power Solutions is first to recognise the growing pressure on data centres to control power consumption and increase energy efficiency.
SuperCaps The SuperCaps© Advantage Combination Architecture© from AEG Power Solutions brings you the SuperCaps© advantage to deliver a highly effective energy storage solution for data centres and mission critical power applications. SuperCaps© (or ultracapacitors) provide an environmentally effective option for businesses that are concerned with reducing energy consumption, lowering total cost of ownership and carbon footprint.
16 38 Protect 3.M 2.0 Power Safety Protect 3.M 2.0: Modular UPS system for medium A technically convincing solution that is flexible to fulfill the growing requirements of modern datacenters: r Sufficient power and security reserves r Easy handling and low maintenance costs r Optimal price-performance ratio Power failures, overloads and undervoltage can lead in the worst case to loss of data.
Protect 3.M 2.0 -sized datacenters Classification VFI SS 111 acc. to IEC 62040-3 Type power Max. modules per rack Protect 3.M 80 Protect 3.M 120 80 kVA 120 kVA 64 KW 96 KW 4 6 UPS INPUT Input voltage Frequency Frequency range Power factor THD (i) 400/230Vac 50/60Hz (Auto-Selectable) +/-5 Hz > 0.99 (Full Load) <5% UPS OUTPUT Rated output voltage Frequency THD (v) Transfer time at mains outage Voltage waveform 400/230Vac 50/60Hz +/-0,05% ≤3% 0 ms (zero transfer) sinusoidal <125% for 10 min.
16 40 Protect 3.33 Power Safety Protect 3.33: Online UPS system for datacenters a Robust and Reliable Protect 3.33 is extremely robust, both electrically and mechanically. It is custom-designed for use in harsh industrial environments.
Protect 3.33 nd internet nodes MODEL Type power (at cos ϕ 0.8 lag) in kVA 3.33-10 3.33-20 3.33-30 3.33-40 3.33-60 3.33-80 3.33-100 3.33-120 10 20 30 40 60 80 100 120 130 163 195 123 164 205 246 6 pulse Filter 6 pulse 12 pulse 6 pulse 12 pulse 6 pulse 12 pulse 116 145 173 80 100 120 1710 1815 1200 735 800 1710 1815 1200 735 900 1710 1815 1200 735 900 RECTIFIER UNIT Input nominal voltage operating range (min./max.
16 42 Protect 4.33 Power Safety Protect 4.
Protect 4.33 ters and internet nodes Type power at cos ϕ 0,8 lag. in kVA 160 220 300 400 500 600 800 1000 811 1025 973 1230 1300 1600 1624 2000 12 12 12 12 723 867 1156 1445 3 x 380/400/415 50/60 400 500 600 800 1000 1960 2210 2400 960 3800 2210 2210 4050 1060 5700 RECTIFIER UNIT Nominal voltage in V Operating range min./max. in V Frequency in Hz Input current in A at nominal load Input current in A at nominal load + battery charging Charging characteristic acc.
CompuWatch Ease of use Software solutions „CompuWatch“ – the Shutdown- and UPS management software … for automation in data processing. Based on the TCP/IP network protocol, CompuWatch is applicable to heterogeneous networks where servers and computer systems with diverse operating systems require a safe (i.e. where all open files are closed) and automatic shutdown process for particular situations.
Network-Management-Software Control of datacenters with UPS management Smoke detector Motion detector Temperature sensor Access control UPS with SNMP adapter Hamburg Berlin Server farm SSL encryption Intranet Frankfurt UPSMonitor Administrator At failure: alarm via e-mail or pop-up. Munich Web based AEG Network Management Software Network management for UPS devices Integrated solution of UPS management … a solution for intelligent network management.
Accessories: Hardware Ease of use Hardware: Extensions & accessories Part numbers Remote Panel Power distribution units Remote signal indicator for professional datacenter management Power distribution for professional datacenters The remote panel displays remote UPS status in real time. An additional bar graph shows the current UPS load and remaining capacity in emergency power mode.
Accessories: Hardware Manual Bypass Switch Power Distribution Box Manual bypass switch for maintenance and battery tests Parallel board, manual bypass and distribution The external manual bypass switch, an optional add-on for the Protect B., B. PRO, C., C.R, D., 1. and 1.M series of UPS systems, is used to bypass a UPS – for example, to carry out maintenance – without interrupting the supply of power to connected loads.
Accessories: Communication Ease of use Communication: Extensions & accessories Part numbers Relay card SiteManager Communication device for AS / 400 Network based UPS management device This relay card is an option for UPS series Protect B./B. PRO/C./C.R/D./1. and 1.M and enables the communication via potential free contacts. The contacts can be configured as open and shut. The status notifications will be transmitted by a 9 pin Sub-D socket.
Accessories: Communication Environment Manager SNMP(pro) Adapter Management device for several environment sensors UPS management device via network The Environment Manager is a universal sensor management device designed as a system add-on for the SNMP PRO Adapter. It can manage up to eight analog sensors, four digital contacts and four digital switches simultaneously.
Service: Compact UPS Competence Service: Your Power Partner for reliability „Only a professionally serviced and maintained UPS offers the highest possible availability with effective cost control.“ Based on our high standards and decades of experience, we are also cost-effective, efficient and rapid when it comes to servicing. Pro-Care Comfort Maintenance service for PROTECT C, 1 and 1.M. Can be ordered as a service package at any time.
Service: 3 phase UPS Rely on the experts to reduce failure costs and increase system availability Because AEG Power Solutions is a world class system provider, you can rely on a global network of 20 Services Centers supported by over 150 field engineers and more than 100 certified service partners around the world. From power solution selection to process installation and commissioning, our certified experts exceed your expectations.
Toronto, Canada Prague, Czech Republic Budapest, Hungary Lannion, France Paris, France Vitoria, Spain Madrid, Spain Moscow, Russia Chambray-lésVimercateTours, Milan, France Italy Beijing, China Dallas, Texas Shanghai, China Chengdu, China Mexico Dubai, United Arab Emirates Hong Kong, China Bengalor, India Penang, Malaysia Singapore Capetown, South Africa PERFECT IN FORM AND FUNCTION Mayflex UK Ltd Excel House, Junction Six Industrial Park Electric Avenue, BIRMINGHAM, B6 7JJ, United Kingdom Tel: