Safety Instructions for the Installer
The mains connection must be with a cable with a plug or there must be a
disconnecting device with at least 3 mm contact opening in the existing
domestic electrical installation, which disconnects the dishwasher comple−
tely from the mains supply in accordance with NIN 2000.
In respect of fire protection, this appliance corresponds to type Y (EN 60
335−2−6). Only this type of appliance may be installed with a high cupbo−
ard or wall on one side.
It is not permitted to fit drawers below the cooking surface.
Protection against electric shock must be provided by the installation.
The kitchen unit in which the appliance is fitted must satisfy the require−
ments of DIN 68930 in respect of stability.
Built−in ovens and cooking surfaces are fitted with special connector sy−
stems. They may only be combined with appliances with a matching system.
All cut surfaces are to be sealed with a suitable sealant for protection
against moisture.
On tiled work surfaces, the joints in the area where the hob sits on the sur−
face must be completely filled with grout.
On natural, artificial stone, or ceramic tops, the snap action springs must be
bonded in place.
Ensure that the seal is correctly seated in the frame and that it is seated
against the work surface without leaving any gaps. Additional silicon sea−
lant must not be applied, this will make removal more difficult in the event
of the need for service.