Service manual

Service-Bulletin
DGS-TDS-N © Electrolux
13.02.06
599 525 778 ENCookers
Induction hobs „G4“
Problem description: If you do not stick the transport safety adhesive on the coil connection cover after
repairs, the high-frequency magnetic field can lead to a temperature rise in the coil
area. The coil can be damaged by this. In order to eliminate this problem altogether,
you should not reapply the transport-safety adhesive tape after repairs.
The figure shows improper adhesion which may lead to damage from overheating of the coil located on top.
Transport safety adhesive tape before repair Do not apply adhesive tape after repair